Advanced Biosafety Pass Boxes by QUALIA: Ensuring Sterile Transfers in High-Risk Environments

In the realm of biological safety, the transfer of materials between areas of different safety levels is a critical process that requires meticulous attention to detail. QUALIA’s Biosafety Pass Boxes are designed to meet these stringent requirements, providing a robust and efficient solution for laboratories and medical facilities.

Key Features of QUALIA Biosafety Pass Boxes

Sealing Options and Integrity

QUALIA’s Biosafety Pass Boxes offer two sealing options: inflatable seals and mechanical compression. The inflatable seals are made from high-density EPDM (Ethylene Propylene Diene Monomer) with a hardness of 60±5° Shore A, ensuring a long service life of over 5 years. These seals maintain a pressure decay of less than 0.5% Vol/h at ±2000Pa over 20 minutes, exceeding industry standards.

Sterilization Methods

These pass boxes are equipped with multiple sterilization methods, including UV disinfection lamps and VHP (Vaporized Hydrogen Peroxide) disinfection ports. The VHP system, which can be connected to an external VHP generator, ensures thorough sterilization by producing a hydrogen peroxide mist that effectively kills a wide range of microorganisms, including bacteria, viruses, fungi, and spores.

Door Construction and Safety

The doors of the pass boxes are constructed from fully welded 3.0mm stainless steel sheets and feature double-layer 5mm tempered glass. The design includes concentric circle corners with inner rounded arc welds and thorough sanding to ensure user safety and minimize the risk of glass breakage.

Advanced Features

  • Temperature Stability: An optional feature maintains temperature variations within ≤3℃, ideal for sensitive biological transfers like serum.
  • Functionality Switch: Users can switch between VHP sterilization and standard self-cleaning UV modes via a touchscreen.
  • BMS Communication: The pass boxes facilitate integration with BMS systems for online and remote printing, as well as data storage capabilities.

Technical Specifications

FeatureSpecification
Seal Integrity±2000Pa with <0.5% Vol/h decay over 20 minutes
Seal MaterialHigh-density EPDM (60±5° Shore A)
Seal Service Life≥5 years
Door MaterialFully welded 3.0mm stainless steel and double-layer 5mm tempered glass
Sterilization MethodsUV disinfection lamps and VHP (Vaporized Hydrogen Peroxide)
Temperature StabilityOptional: ≤3℃ variation
BMS CommunicationOnline and remote printing, data storage
Power SupplySingle-phase AC 220V/50Hz

Efficiency and Versatility

QUALIA’s Biosafety Pass Boxes are designed for efficiency and versatility. The VHP sterilization cycle, including residual removal, can be completed in as little as 30 minutes, reducing processing time by 50%-70% compared to similar market offerings.

Independent Air Supply and Exhaust

The units are built with standalone air ducts, including integrated supply, exhaust, and recirculation fans, which can connect to customer HVAC systems. This ensures a controlled environment during the sterilization process.

Conclusion

QUALIA’s Biosafety Pass Boxes are a testament to innovative design and technological advancement in biological safety. With their robust sealing options, advanced sterilization methods, and user-friendly features, these pass boxes are essential for any laboratory or medical facility requiring high-level biological safety. Whether you need to transfer sensitive biological materials or ensure the sterility of equipment, QUALIA’s Biosafety Pass Boxes provide a reliable and efficient solution.

Scroll to Top
In the realm of pharmaceutical manufacturing and laboratory research, maintaining a sterile and safe environment is paramount. The OEB4/OEB5 Isolator stands at the forefront of containment technology, utilizing advanced filtration systems to ensure the highest levels of safety and sterility. This article delves into the comparison between two cutting-edge filtration systems: PUSH-PUSH and BIBO (Bag-In Bag-Out), exploring their roles in creating optimal conditions within these critical containment units. | qualia logo 1