Bio-safety lsolation Damper

Bio-safety lsolation Damper | QUALIA Bio-safety lsolation Damper 2_1

What is the Bio-safety Isolation Damper?

The Bio-safety Isolation Damper serves a critical role in modulating or halting airflow within a system to mitigate the risk of pathogenic microorganism leakage. The dampers are categorized into manual and electric types based on their actuation mechanism. The electrically operated isolation dampers can automatically regulate airflow in conjunction with a control system, ensuring air-tightness even in the event of power failure.

Compliant with ISO10648-2 “Containment enclosures – Part 2: Classification according to leak tightness and associated checking methods” and GB 50346-2011 “Technical specifications for biosafety laboratory construction”, these dampers are tailored to meet diverse user requirements and come in both circular and rectangular shapes. Moreover, the dimensions of the airtight valve can be customized to accommodate the specific needs of customers.

Bio-safety lsolation Damper | Qualia Bio-safety lsolation Damper 7

Product Features

  • Air Tightness: At a pressure of ±5000Pa, the leakage rate does not exceed 0.25% of the net volume per hour.
  • Pressure Resistance: The valve box can withstand a pressure of -5000Pa for 60 minutes without permanent structural deformation.
  • Service Life: After 10,000 cycles of opening and closing, the valve passes the air tightness test under positive and negative pressure, complying with national standards.
  • Corrosion Resistance: All components of the valve can withstand the corrosion of disinfectants such as hydrogen peroxide, chlorine dioxide, and formaldehyde. After the corrosion test, air tightness still meets national specifications.
  • Resistance: With the valve fully open at the rated airflow, resistance does not exceed 40Pa.

Square Biosafety Sealed Value

Bio-safety lsolation Damper | Qualia Bio-safety lsolation Damper 5
ModelInner diameterDepthAxial lengthFlange widthFlange Thickness
QL-VF-I250*320300395505
QL-VF-II320*500300495505
QL-VF-III320*800500695505
QL-VF-IV630*800500895505
QL-VF-V500*10005001195505
QL-VF-VI630*12005001295505

Circular Biosafety Sealed Value

Bio-safety lsolation Damper | Qualia Bio-safety lsolation Damper 2
ModelInner diameterDepthAxial lengthFlange widthFlange Thickness
QL-VY-I500300695505
QL-VY-II600300795505
QL-VY-III700500895505
QL-VY-IV800500995505
QL-VY-V10005001195505
QL-VY-VI12005001295505