{"id":8590,"date":"2026-11-24T00:11:10","date_gmt":"2026-11-23T16:11:10","guid":{"rendered":"https:\/\/qualia-bio.com\/blog\/which-cleaning-agents-and-contact-surfaces-should-be-reviewed-before-choosing-a-pass-box-door-seal\/"},"modified":"2026-11-24T00:11:11","modified_gmt":"2026-11-23T16:11:11","slug":"which-cleaning-agents-and-contact-surfaces-should-be-reviewed-before-choosing-a-pass-box-door-seal","status":"publish","type":"post","link":"https:\/\/qualia-bio.com\/tr\/blog\/which-cleaning-agents-and-contact-surfaces-should-be-reviewed-before-choosing-a-pass-box-door-seal\/","title":{"rendered":"Ge\u00e7i\u015f Kutusu Kap\u0131 Contas\u0131 Se\u00e7ilmeden \u00d6nce Hangi Temizlik Maddeleri ve Temas Y\u00fczeyleri \u0130ncelenmelidir?"},"content":{"rendered":"<p>Bir ge\u00e7i\u015f kutusu kap\u0131 contas\u0131 se\u00e7meden \u00f6nce, bu contayla temas edecek her temizlik ve dezenfeksiyon maddesini \u2014\u00fcr\u00fcn ad\u0131 ve form\u00fclasyonuna g\u00f6re\u2014 ve bu maddelerin ula\u015faca\u011f\u0131 her y\u00fczeyi (sadece elastomer de\u011fil, \u00e7er\u00e7eve ve donan\u0131m dahil) g\u00f6zden ge\u00e7irin. Cevap, tesisinizde ger\u00e7ekte neyin kullan\u0131ld\u0131\u011f\u0131na, nas\u0131l uyguland\u0131\u011f\u0131na ve tedarik\u00e7inin o belirli kombinasyon i\u00e7in ne t\u00fcr bir performans kan\u0131tlayabilece\u011fine ba\u011fl\u0131d\u0131r. Yaln\u0131zca geni\u015f bir kimyasal grubu belirten veya \u201ctesis uyumlulu\u011funa\u201d at\u0131fta bulunan projelerde, temizlik uygulamalar\u0131 belirlendikten sonra rutin olarak malzeme eksiklikleri ortaya \u00e7\u0131kar.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"listcleaningagentsandtheirdocumenteduse\">Temizlik Maddeleri ve Belgelenmi\u015f Kullan\u0131m Alanlar\u0131<\/h2>\n<p>\u0130lk g\u00f6rev, ge\u00e7i\u015f kutusuyla temas edecek her bir maddenin, genel bir kimyasal s\u0131n\u0131f de\u011fil, tan\u0131mlanabilir bir form\u00fclasyon belgesine at\u0131fta bulunularak haz\u0131rlanm\u0131\u015f eksiksiz bir yaz\u0131l\u0131 listesini olu\u015fturmakt\u0131r.<\/p>\n<p>Bir ihale dosyas\u0131nda veya tasar\u0131m talimat\u0131nda yaln\u0131zca \u201c\u015fantiye temizlik maddeleriyle uyumlu\u201d ifadesi yer al\u0131yorsa, bu ifade de\u011ferlendirilemez. Bu talebi alan bir tedarik\u00e7inin yan\u0131t\u0131 i\u00e7in belirgin bir dayana\u011f\u0131 olmaz ve sizin de tedarik\u00e7inin sundu\u011fu kan\u0131tlar\u0131 incelemek i\u00e7in bir dayana\u011f\u0131n\u0131z olmaz. Herhangi bir uyumluluk talebi g\u00f6nderilmeden \u00f6nce, her bir temizlik maddesini \u00fcr\u00fcn ad\u0131 veya kontroll\u00fc form\u00fclasyon tan\u0131mlay\u0131c\u0131s\u0131, i\u00e7eri\u011fini a\u00e7\u0131klayan form\u00fclasyon belgesi referans\u0131 ve revizyon numaras\u0131 ile uygulama \u015feklini belirleyen tesis kullan\u0131m talimatlar\u0131 (konsantrasyon, etki s\u00fcresi, s\u0131cakl\u0131k ve s\u0131kl\u0131k) ile birlikte kaydeden bir liste haz\u0131rlay\u0131n. Uyumluluk incelemesi, yeni ko\u015fullar uydurmak yerine, tesis taraf\u0131ndan onaylanm\u0131\u015f bu ko\u015fullar\u0131 esas al\u0131r.<\/p>\n<p><strong>\u0130lgili \u00dcr\u00fcnler<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/qualia-bio.com\/tr\/product\/passseries\/biosafety-pass-box\/\">Biyog\u00fcvenlik Ge\u00e7i\u015f Kutusu<\/a> \u2014 Yap\u0131land\u0131rmaya \u00f6zg\u00fc bir teklif talebini ba\u015flatmak i\u00e7in ilgili montaj listesini kullan\u0131n; conta t\u00fcr\u00fc, donan\u0131m, yard\u0131mc\u0131 hizmetler, yedek par\u00e7alar ve hizmet kapsam\u0131 hakk\u0131nda ayr\u0131nt\u0131l\u0131 bir yan\u0131t verilmesi gerekmektedir.<\/li>\n<\/ul>\n<p>Temiz oda ve kontroll\u00fc ortam ge\u00e7i\u015f kutular\u0131nda yayg\u0131n olarak kullan\u0131lan maddeler aras\u0131nda alkoller, kuaterner amonyum bile\u015fikleri, klor bazl\u0131 dezenfektanlar, perasetik asit \u00e7\u00f6zeltileri ve \u2014 VHP (buharla\u015ft\u0131r\u0131lm\u0131\u015f hidrojen peroksit) transfer dekontaminasyonunun kapsamda oldu\u011fu durumlarda \u2014 hem s\u0131v\u0131 mendil hem de buhar formundaki hidrojen peroksit yer al\u0131r. Bunlar, elastomerler ve donan\u0131m \u00fczerindeki etkileri bak\u0131m\u0131ndan birbirinin yerine kullan\u0131lamaz. Ayn\u0131 elastomer ailesi, tekrarlanan klor maruziyeti alt\u0131nda alkole k\u0131yasla \u00e7ok farkl\u0131 davran\u0131\u015flar sergileyebilir ve bir VHP ge\u00e7i\u015f kutusunun i\u00e7inde ula\u015f\u0131lan buhar faz\u0131 hidrojen peroksit konsantrasyonlar\u0131, y\u00fczey mendillerindekinden \u00f6nemli \u00f6l\u00e7\u00fcde daha y\u00fcksektir. Her bir madde ve her bir uygulama y\u00f6ntemi, kendi kay\u0131t girdisine ait olmal\u0131d\u0131r.<\/p>\n<blockquote>\n<p>Tedarik\u00e7iye uyumluluk talebinde bulunmadan \u00f6nce, her bir aktif maddeyi, kontroll\u00fc form\u00fclasyon referans\u0131 ve kullan\u0131m talimat\u0131 revizyon numaras\u0131yla birlikte kaydedin; kimyasal s\u0131n\u0131f ad\u0131, inceleme i\u00e7in yeterli bir dayanak de\u011fildir.<\/p>\n<\/blockquote>\n<p>Form\u00fclasyon ayr\u0131nt\u0131lar\u0131 ticari gizlilik kapsam\u0131ndaysa, kay\u0131t defterinde tam bile\u015fim yerine \u00fczerinde mutab\u0131k kal\u0131nan bir kontroll\u00fc if\u015fa referans\u0131 belirtilebilir. Atlanmamas\u0131 gereken unsurlar ise aktif maddenin kimli\u011fi ve kullan\u0131m ko\u015fullar\u0131d\u0131r: bu ikisi olmadan, tedarik\u00e7inin verdi\u011fi yan\u0131t\u0131n do\u011frulanmas\u0131 m\u00fcmk\u00fcn de\u011fildir.<\/p>\n<p>Sorgulama an\u0131nda temizlik uygulamas\u0131 h\u00e2l\u00e2 kurum i\u00e7i inceleme a\u015famas\u0131ndaysa, hangi kullan\u0131m bilgilerinin eksik oldu\u011funu belirten \u015fartl\u0131 bir tedarik\u00e7i yan\u0131t\u0131 isteyin. \u201dBekleme s\u00fcresi X'i a\u015fmazsa, konsantrasyon Y aral\u0131\u011f\u0131nda kal\u0131rsa ve y\u00fczey s\u0131cakl\u0131\u011f\u0131 Z'nin alt\u0131ndaysa uyumlulu\u011fu teyit edebiliriz\u201d \u015feklindeki ko\u015fullu bir kar\u015f\u0131la\u015ft\u0131rma, tan\u0131mlanm\u0131\u015f ko\u015fullara g\u00f6re hi\u00e7bir zaman test edilmemi\u015f genel bir uyumluluk vaadinden \u00e7ok daha yararl\u0131d\u0131r. Temizlik SOP'leri kesinle\u015fmeden \u00f6nce ekipman \u00f6zelliklerini sabitleyen projeler, giderek daha fazla bu t\u00fcr ko\u015fullu yan\u0131tlar talep etmektedir ve b\u00f6yle bir yan\u0131t verebilen tedarik\u00e7iler, kan\u0131tlar\u0131n\u0131n genel nitelikte de\u011fil, izlenebilir oldu\u011funu g\u00f6stermi\u015f olurlar.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"identifysealandcontactsurfacematerials\">Conta ve Temas Y\u00fczeyi Malzemelerini Belirleyin<\/h2>\n<p>M\u00fch\u00fcr, birka\u00e7 y\u00fczeyden sadece biridir ve <strong>t\u00fcm temas eden y\u00fczeyler<\/strong> Uyumluluk incelemesinin tamamlanabilmesi i\u00e7in bunlar\u0131n tespit edilmesi gerekmektedir.<\/p>\n<p>\u201dSilikon\u201d, \u201cEPDM\u201d, \u201cfloroelastomer\u201d gibi geni\u015f malzeme ailesi isimleri, kimyasal diren\u00e7 profilleri a\u00e7\u0131s\u0131ndan \u00f6nemli \u00f6l\u00e7\u00fcde farkl\u0131l\u0131k g\u00f6steren bir dizi form\u00fclasyonu kapsar. Bir tedarik\u00e7i bir kap\u0131 contas\u0131n\u0131 yaln\u0131zca aile ad\u0131yla tan\u0131mlad\u0131\u011f\u0131nda, teklif edilen malzemenin spesifik tan\u0131mlay\u0131c\u0131s\u0131n\u0131 isteyin: tedarik edilen par\u00e7ay\u0131 ayn\u0131 ailenin di\u011fer \u00fcyelerinden ay\u0131ran kalite derecesi, bile\u015fik tan\u0131m\u0131 veya kontroll\u00fc bile\u015fen spesifikasyonu. Bu tan\u0131mlay\u0131c\u0131, contay\u0131 tedarik\u00e7inin elindeki herhangi bir test veya hizmet verisiyle ili\u015fkilendiren unsurdur. Bir malzeme ailesi etiketi, ayn\u0131 ad\u0131 payla\u015fan ancak plastikle\u015ftirici i\u00e7eri\u011fi, dolgu maddesi veya k\u00fcrleme sistemi bak\u0131m\u0131ndan farkl\u0131l\u0131k g\u00f6steren bile\u015fenler aras\u0131ndaki farklar\u0131 gizleyebilir; bu farkl\u0131l\u0131klar\u0131n her biri, tekrarlanan dezenfeksiyon d\u00f6ng\u00fcleri alt\u0131nda \u00e7\u00f6z\u00fcc\u00fc direncini veya oksidatif kararl\u0131l\u0131\u011f\u0131 etkiler.<\/p>\n<p>Temas eden tek malzeme sadece conta malzemesi de\u011fildir. Temizlik maddeleri p\u00fcsk\u00fcrtme, silme veya dald\u0131rma yoluyla uyguland\u0131\u011f\u0131nda \u015fu yerlere ula\u015f\u0131r:<\/p>\n<ul>\n<li>\u015fu <strong>kap\u0131 \u00e7er\u00e7evesi<\/strong>, e\u015fikteki a\u00e7\u0131kta kalan metal k\u0131s\u0131mlar, kaplamal\u0131 y\u00fczeyler veya kaynakl\u0131 birle\u015fim yerleri dahil olmak \u00fczere;<\/li>\n<li><strong>mente\u015fe ve mandal donan\u0131m\u0131<\/strong>, bu farkl\u0131 bir paslanmaz \u00e7elik kalitesi veya kaplamal\u0131 bir par\u00e7a olabilir;<\/li>\n<li>herhangi bir <strong>conta veya ikincil s\u0131zd\u0131rmazl\u0131k eleman\u0131<\/strong> bir g\u00f6r\u00fcnt\u00fcleme panelinde veya g\u00f6sterge yuvas\u0131nda;<\/li>\n<li>\u015fu <strong>i\u00e7 astar y\u00fczeyi<\/strong>, \u00f6zellikle su birikintisi olu\u015fabilecek zemin ve k\u00f6\u015felerde.<\/li>\n<\/ul>\n<p>Yaln\u0131zca contayla ilgili bir uyumluluk beyan\u0131, t\u00fcm bu y\u00fczeyleri belirtilen inceleme kapsam\u0131 d\u0131\u015f\u0131nda b\u0131rak\u0131r. Pn\u00f6matik contal\u0131 ge\u00e7i\u015f kutular\u0131nda \u2014\u015fi\u015firme sisteminin hortumlar, ba\u011flant\u0131 par\u00e7alar\u0131 ve bir \u015fi\u015firme ba\u011flant\u0131 noktas\u0131 d\u00fczene\u011fi ekledi\u011fi durumlarda\u2014 maddeyle temas eden bile\u015fenler listesi, bu bile\u015fenleri ve bunlar\u0131n yap\u0131ld\u0131\u011f\u0131 malzemeleri de i\u00e7erir.<\/p>\n<p>Ekibin, kullan\u0131lan perasetik asit dezenfektan\u0131yla ilgili sa\u011flam uyumluluk verilerine dayanarak bir florelastomer kap\u0131 contas\u0131 se\u00e7ti\u011fi bir projeyi ele alal\u0131m. Uyumluluk beyan\u0131, contan\u0131n elastomerini kapsamaktad\u0131r. Kurulumdan sonra, temizlik ekibi ayn\u0131 dezenfektan\u0131 kap\u0131 \u00e7er\u00e7evesi ve mandal tertibat\u0131 \u00fczerinde silerek temizler; bu bile\u015fenler, orijinal malzeme listesinde belirtilen paslanmaz \u00e7elik yerine boyal\u0131 y\u00fczeyli karbon \u00e7eli\u011finden yap\u0131lm\u0131\u015ft\u0131r. Boya birka\u00e7 ay i\u00e7inde bozulur. Sorun hi\u00e7bir zaman contada de\u011fildi; \u00e7er\u00e7eve malzemesi hi\u00e7bir zaman incelenmemi\u015fti. Ba\u015flang\u0131\u00e7ta t\u00fcm temas y\u00fczeylerinin envanterinin dahil edilmesi, ekipman sipari\u015f edilmeden \u00f6nce bu sorunun fark edilmesini sa\u011flayabilirdi.<\/p>\n<h2 id=\"requestconfigurationspecificcompatibilityevidence\">Yap\u0131land\u0131rmaya \u00d6zg\u00fc Uyumluluk Kan\u0131t\u0131 Talebi<\/h2>\n<p>Uyumluluk kan\u0131t\u0131, ancak her bir madde i\u00e7in belirli bir etken, belirli bir y\u00fczey ve belirli bir sunulan malzeme ile ili\u015fkilendirilebildi\u011finde anlaml\u0131d\u0131r.<\/p>\n<p>Bir tedarik\u00e7i uyumluluk verileri sundu\u011funda, her sat\u0131r\u0131n veya giri\u015fin a\u015fa\u011f\u0131dakileri belirtecek \u015fekilde yap\u0131land\u0131r\u0131lm\u0131\u015f bir yan\u0131t isteyin: aktif maddenin \u00fcr\u00fcn ad\u0131 veya form\u00fclasyon referans\u0131, incelemenin dayand\u0131\u011f\u0131 kullan\u0131m talimat\u0131 revizyonu, temas eden y\u00fczey (kap\u0131 contas\u0131, \u00e7er\u00e7eve, donan\u0131m), o y\u00fczey i\u00e7in \u00f6nerilen malzeme tan\u0131mlay\u0131c\u0131s\u0131, tedarik\u00e7inin kan\u0131t referans\u0131 ve bu kan\u0131t\u0131n belirtilen kapsam\u0131. Bu yap\u0131 olmadan, hangi aktif madde-y\u00fczey kombinasyonlar\u0131n\u0131n do\u011fruland\u0131\u011f\u0131 ve hangilerinin hen\u00fcz yan\u0131tlanmam\u0131\u015f oldu\u011fu anla\u015f\u0131lamaz. \u201cMalzemeler standart dezenfektanlarla uyumludur\u201d ifadesini i\u00e7eren bir belge, belirli bir elastomer s\u0131n\u0131f\u0131nda 10 dakikal\u0131k bekleme s\u00fcresi ile 2% konsantrasyonundaki perasetik asit hakk\u0131nda hi\u00e7bir bilgi vermez.<\/p>\n<p><strong>Yap\u0131land\u0131rmaya \u00d6zg\u00fc Uyumluluk Kan\u0131t\u0131 Talebi: Al\u0131c\u0131 De\u011ferlendirme Matrisi<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>\u00d6rnek kay\u0131t alan\u0131<\/th>\n<th>Yaln\u0131zca \u00f6rnek ama\u00e7l\u0131 bir giri\u015f<\/th>\n<th>Tedarik\u00e7inin yan\u0131t\u0131 bekleniyor<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ajan\u0131n kimli\u011fi<\/td>\n<td>A Temsilcisi; F-A numaral\u0131 \u00fcr\u00fcn veya form\u00fclasyon kayd\u0131; onay i\u00e7in revizyon<\/td>\n<td>Yan\u0131tta kullan\u0131lan form\u00fclasyon temelini belirleyin<\/td>\n<\/tr>\n<tr>\n<td>Sitenin kullan\u0131m\u0131<\/td>\n<td>CLEAN-A talimat\u0131; onay i\u00e7in revizyon<\/td>\n<td>Ekte verilen onayl\u0131 kullan\u0131m ba\u011flam\u0131na ba\u015fvurun<\/td>\n<\/tr>\n<tr>\n<td>Temas eden y\u00fczey<\/td>\n<td>Kap\u0131 contas\u0131; teyit i\u00e7in sunulan malzeme tan\u0131mlay\u0131c\u0131s\u0131<\/td>\n<td>Yan\u0131t\u0131, sunulan ger\u00e7ek materyalle ili\u015fkilendirin<\/td>\n<\/tr>\n<tr>\n<td>Di\u011fer temas eden y\u00fczey<\/td>\n<td>\u00c7er\u00e7eve veya donan\u0131m; do\u011frulama i\u00e7in malzeme tan\u0131mlay\u0131c\u0131s\u0131<\/td>\n<td>Bu y\u00fczeyin kapal\u0131 m\u0131 yoksa a\u00e7\u0131k m\u0131 oldu\u011funu belirtin<\/td>\n<\/tr>\n<tr>\n<td>Kan\u0131tlar<\/td>\n<td>Tedarik\u00e7i kan\u0131t referans\u0131 beklemede<\/td>\n<td>Kapsam\u0131 ve hen\u00fcz cevaplanmam\u0131\u015f t\u00fcm ajan-y\u00fczey kombinasyonlar\u0131 g\u00f6z \u00f6n\u00fcne al\u0131nd\u0131\u011f\u0131nda<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kay\u0131t sistemini yap\u0131land\u0131rmak i\u00e7in faydal\u0131 ve a\u00e7\u0131klay\u0131c\u0131 bir ba\u015flang\u0131\u00e7 noktas\u0131 \u015f\u00f6yle olabilir: <strong>A Ajan\u0131<\/strong>, F-A numaral\u0131 form\u00fclasyon kayd\u0131n\u0131n revizyonunun onaylanmas\u0131, CLEAN-A numaral\u0131 tesis kullan\u0131m talimat\u0131n\u0131n revizyonunun onaylanmas\u0131, kap\u0131 contas\u0131 y\u00fczeyi, sunulan malzeme tan\u0131mlay\u0131c\u0131s\u0131n\u0131n onaylanmas\u0131, tedarik\u00e7i kan\u0131t referans\u0131 beklemede. Bu giri\u015f bi\u00e7imi, proje kapsam\u0131nda hen\u00fcz tan\u0131mlanmam\u0131\u015f belirli bir madde veya malzemeye at\u0131fta bulunmadan, bilgilerin tam olarak hangi k\u0131s\u0131mlarda eksik oldu\u011funu ortaya koyar. Ger\u00e7ek talebi g\u00f6ndermeden \u00f6nce, bu \u00f6rnek etiketleri kontroll\u00fc proje referanslar\u0131yla de\u011fi\u015ftirin.<\/p>\n<blockquote>\n<p>Kan\u0131t talebi, genel bir a\u00e7\u0131klama de\u011fil, doldurulmu\u015f bir matris d\u00f6nd\u00fcrmelidir; her bo\u015f h\u00fccre, yan\u0131tlanmam\u0131\u015f bir kombinasyondur.<\/p>\n<\/blockquote>\n<p>QUALIA ge\u00e7i\u015f kutular\u0131, pn\u00f6matik veya mekanik kap\u0131 contalar\u0131yla yap\u0131land\u0131r\u0131labilir ve bu iki tasar\u0131m aras\u0131nda temas y\u00fczeyi bile\u015fenleri farkl\u0131l\u0131k g\u00f6sterir. Pn\u00f6matik contalarda, \u015fi\u015firme sistemi, standart malzeme listesinde yer alabilen veya almayabilen bile\u015fenler ekler. Mekanik contalarda ise, elastomerin yan\u0131 s\u0131ra s\u0131k\u0131\u015ft\u0131rma aray\u00fcz\u00fc ve bunu \u00e7al\u0131\u015ft\u0131ran donan\u0131m ba\u015fl\u0131ca hususlard\u0131r. Uyumluluk talebi, sunulan konfig\u00fcrasyonu yans\u0131tmal\u0131 ve tedarik\u00e7i, bu \u015fartlar \u00e7er\u00e7evesinde kan\u0131t kapsam\u0131n\u0131 belirlemelidir.<\/p>\n<p>Tedarik\u00e7inin belirli bir kombinasyonu teyit edemedi\u011fi durumlarda \u2014testlerin yap\u0131lmam\u0131\u015f olmas\u0131, maddenin do\u011frulanm\u0131\u015f aral\u0131\u011f\u0131n d\u0131\u015f\u0131nda kalmas\u0131 ya da bir bile\u015fen malzemesinin alt y\u00fckleniciden temin edilmesi gibi nedenlerle\u2014 bu eksiklik yan\u0131tta a\u00e7\u0131k\u00e7a belirtilmelidir. Ko\u015fullu bir yan\u0131t ya da \u201cbilinmeyen\u201d olarak kabul edilen bir durum, projede kullan\u0131labilir bir \u00e7\u0131kt\u0131d\u0131r. Kan\u0131tlarla desteklenemeyen ko\u015fulsuz bir iddia ise de\u011fildir.<\/p>\n<p><strong>\u0130lgili Makaleler<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/qualia-bio.com\/tr\/blog\/urs-for-high-containment-equipment-what-qa-engineering-and-procurement-should-define-before-rfq\/\">Y\u00fcksek G\u00fcvenlikli Ekipmanlar i\u00e7in URS: Teklif Talebi (RFQ) \u00d6ncesinde Kalite G\u00fcvencesi, M\u00fchendislik ve Tedarik Birimlerinin Belirlemesi Gerekenler<\/a> \u2014 Teklif vermeden \u00f6nce, temizlik ama\u00e7lar\u0131n\u0131 al\u0131c\u0131 bilgileri olarak belirtin.<\/li>\n<li><a href=\"https:\/\/qualia-bio.com\/tr\/blog\/vacu-pass-materials-cleaning-and-fumigation-evidence-to-request\/\">Vacu-Pass Malzemeleri: Talep Edilmesi Gereken Temizlik ve Fumigasyon Kan\u0131tlar\u0131<\/a> \u2014 Yan\u0131ndaki bile\u015fen \u00f6rne\u011fini, maddi delil taleplerini \u00e7er\u00e7evelemek i\u00e7in kullan\u0131n; ge\u00e7i\u015f kutusu uyumlulu\u011fu konusunda bir sonuca varmak i\u00e7in de\u011fil.<\/li>\n<li><a href=\"https:\/\/qualia-bio.com\/tr\/blog\/change-control-checklist-for-containment-equipment-requalification\/\">\u0130zolasyon Ekipmanlar\u0131n\u0131n Yeniden Onaylanmas\u0131 i\u00e7in De\u011fi\u015fiklik Kontrol Kontrol Listesi<\/a> \u2014 Temizlik maddesinde veya malzemesinde yap\u0131lan bir de\u011fi\u015fikli\u011fi belge incelemesine dahil edin.<\/li>\n<\/ul>\n<h2 id=\"coordinatechangesandreplacementinformation\">Koordinat De\u011fi\u015fiklikleri ve De\u011fi\u015ftirme Bilgileri<\/h2>\n<p>Sat\u0131n alma a\u015famas\u0131nda yap\u0131lan bir uyumluluk incelemesi yaln\u0131zca ba\u015flang\u0131\u00e7 niteli\u011finde bir kay\u0131tt\u0131r; bu kayd\u0131n yararl\u0131 olmaya devam edip etmeyece\u011fi, ajan\u0131n veya malzemenin de\u011fi\u015fmesi durumunda ne olaca\u011f\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n<p>Temizlik maddeleri ve dezenfeksiyon protokolleri zamanla de\u011fi\u015fir. Bir tesis, alkol bazl\u0131 bir dezenfektandan klor dioksit \u00e7\u00f6zeltisine ge\u00e7ebilir, bir kontaminasyon olay\u0131n\u0131n ard\u0131ndan yeni bir spor \u00f6ld\u00fcr\u00fcc\u00fc madde kullanmaya ba\u015flayabilir veya izolat\u00f6r entegrasyonunun bir par\u00e7as\u0131 olarak ge\u00e7i\u015f kutusunun i\u00e7 k\u0131sm\u0131n\u0131n VHP ile dekontaminasyonuna ge\u00e7ebilir. Bu de\u011fi\u015fikliklerin her biri, hangi s\u0131zd\u0131rmazl\u0131k ve y\u00fczey malzemelerinin kabul edilebilir oldu\u011funu etkileyebilir. Belirli madde ve malzeme tan\u0131mlay\u0131c\u0131lar\u0131na dayanan orijinal uyumluluk kan\u0131t\u0131, bir de\u011ferlendiricinin neyin de\u011fi\u015fti\u011fini ve yeniden de\u011ferlendirmenin gerekli olup olmad\u0131\u011f\u0131n\u0131 belirlemesini sa\u011flar. Bu kan\u0131t olmadan, yeni madde bilinmeyen bir referans noktas\u0131na g\u00f6re de\u011ferlendirilir.<\/p>\n<p>Bu, \u015funu ifade eder: <strong>devir teslim kayd\u0131<\/strong> Ge\u00e7i\u015f kutusu i\u00e7in \u2014ister tasar\u0131m belgeleri paketinde, ister ekipman dosyas\u0131nda, ister \u015fantiyenin yeterlilik kayd\u0131nda yer als\u0131n\u2014 orijinal etken madde listesi, form\u00fclasyon referanslar\u0131, kullan\u0131m talimat\u0131 revizyonlar\u0131 ve orijinal uyumluluk yan\u0131t\u0131n\u0131n dayand\u0131r\u0131ld\u0131\u011f\u0131 sunulan malzeme tan\u0131mlay\u0131c\u0131lar\u0131 muhafaza edilmelidir. Daha sonra bir yedek malzeme onaylan\u0131rsa, kay\u0131tta orijinal kan\u0131t ba\u011flam\u0131 ile yeni kan\u0131t ba\u011flam\u0131 birlikte yer almal\u0131; biri di\u011ferinin yerine ge\u00e7memelidir.<\/p>\n<p>Yedek contalar\u0131n temin edilebilirli\u011fi, ayn\u0131 tart\u0131\u015fma kapsam\u0131nda ele al\u0131nmas\u0131 gereken ilgili bir pratik sorundur. Uyumluluk amac\u0131yla belirlenen conta malzemesi kimli\u011fi, yedek par\u00e7a temini i\u00e7in gerekli olan teknik \u00f6zellikleridir. Sunulan malzeme, malzeme \u00f6zellikleri belirtilmeksizin yaln\u0131zca bir \u00fcr\u00fcn grubu ad\u0131 veya par\u00e7a numaras\u0131yla tan\u0131mlan\u0131yorsa, ileride verilecek bir yedek sipari\u015fte farkl\u0131 bir partiden farkl\u0131 bir bile\u015fim g\u00f6nderilebilir ve tedarik a\u015famas\u0131nda belirlenen uyumluluk temeli art\u0131k ge\u00e7erli olmaz. Tasar\u0131m a\u015famas\u0131nda kontroll\u00fc malzeme tan\u0131mlay\u0131c\u0131s\u0131n\u0131n talep edilmesi, orijinal kan\u0131tlar\u0131n yan\u0131 s\u0131ra yedek tedarik zincirini de korur.<\/p>\n<p>Ekipman se\u00e7imi s\u0131ras\u0131nda temizlik uygulamas\u0131 hen\u00fcz kesinle\u015fmemi\u015fse, en savunulabilir yakla\u015f\u0131m, ekipman malzeme spesifikasyonunu olas\u0131 en zorlu temizlik maddesi ve kullan\u0131m senaryosuna g\u00f6re sabitlemek, bu varsay\u0131m\u0131 a\u00e7\u0131k\u00e7a belgelemek ve temizlik SOP\u2019si onayland\u0131\u011f\u0131nda kay\u0131tlar\u0131 yeniden g\u00f6zden ge\u00e7irmektir. Hem temizlik maddesi se\u00e7imi hem de malzeme se\u00e7imi kararlar\u0131n\u0131 ayn\u0131 anda a\u00e7\u0131k tutmaya \u00e7al\u0131\u015fan projeler nadiren sorunsuz bir \u015fekilde sonu\u00e7lan\u0131r. Birini sabit tutarken di\u011ferini \u00e7\u00f6z\u00fcme kavu\u015fturmak, kan\u0131t zincirini bozulmadan korumak i\u00e7in pratik bir yoldur.<\/p>\n<p>Bir tedarik\u00e7iye ge\u00e7i\u015f kutusu kap\u0131 contas\u0131n\u0131n uyumlulu\u011funu teyit ettirmek i\u00e7in ba\u015fvurmadan \u00f6nce \u015funlar\u0131 haz\u0131r bulundurun: Kullan\u0131lmas\u0131 planlanan her bir temizlik ve dezenfeksiyon maddesinin \u00fcr\u00fcn ad\u0131 veya form\u00fclasyon referans\u0131 ve revizyon numaras\u0131; her bir maddeye ili\u015fkin tesis i\u00e7i kullan\u0131m talimat\u0131n\u0131n tan\u0131mlay\u0131c\u0131s\u0131 ve revizyon numaras\u0131; bu maddelerin temas edece\u011fi y\u00fczeylerin tam listesi; ve s\u00f6z konusu ge\u00e7i\u015f kutusunun konfig\u00fcrasyon t\u00fcr\u00fc (pn\u00f6matik veya mekanik conta).<\/p>\n<p><strong>Kaynak\u00e7a<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/health.ec.europa.eu\/system\/files\/2022-08\/20220825_gmp-an1_en_0.pdf\">AB GMP Ek 1 \u2013 Steril \u0130la\u00e7lar\u0131n \u00dcretimi (2022)<\/a> \u2014 \u0130ncelemeye tabi tutulacak ekipman ve tesis aray\u00fczlerini belirlemek i\u00e7in steril \u00fcretimde kontaminasyon kontrol\u00fc \u00e7er\u00e7evesini kullan\u0131n; bu \u00e7er\u00e7eve, projeye \u00f6zg\u00fc ge\u00e7i\u015f kutusu veya cRABS kabul de\u011ferleri sa\u011flamaz.<\/li>\n<li><a href=\"https:\/\/health.ec.europa.eu\/system\/files\/2016-11\/2015-10_annex15_0.pdf\">EudraLex Cilt 4 Ek 15 \u2013 Yeterlilik ve Do\u011frulama<\/a> \u2014 Tedarik\u00e7i belgelerini, projeye ili\u015fkin uygunluk ve kabul kararlar\u0131ndan ay\u0131r\u0131n; bildirilen ko\u015fullar ve sapmalar, s\u00f6z konusu sisteme \u00f6zg\u00fc olmaya devam eder.<\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/38264.html\">ISO 14644-7:2004 Ay\u0131rma Cihazlar\u0131<\/a> \u2014 Ay\u0131r\u0131c\u0131 cihaz gerekliliklerini ve m\u00fc\u015fteri-tedarik\u00e7i ile ilgili sorular\u0131, standard\u0131n do\u011frulanm\u0131\u015f \u00f6zet kapsam\u0131 i\u00e7inde ele al\u0131n; ayr\u0131nt\u0131l\u0131 h\u00fck\u00fcmler ve ekipman s\u0131n\u0131rlamalar\u0131 bu \u00f6zetin kapsam\u0131 d\u0131\u015f\u0131ndad\u0131r.<\/li>\n<li><a href=\"https:\/\/www.who.int\/publications\/i\/item\/9789240011311\">DS\u00d6 Laboratuvar Biyog\u00fcvenlik El Kitab\u0131, 4. Bask\u0131 (Temel Belge)<\/a> \u2014 Genel ekipman etiketinden ziyade laboratuvar kullan\u0131m amac\u0131n\u0131 ve risk de\u011ferlendirme esaslar\u0131n\u0131 \u00f6n planda tutun; bu \u00f6zet, bir kap\u0131 spesifikasyonu veya tesis onay\u0131 niteli\u011finde de\u011fildir.<\/li>\n<\/ul>\n<h2 id=\"frequentlyaskedquestions\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<p><strong>Q:<\/strong> Tedarik birimi, malzemeleri farkl\u0131 \u015fekilde tan\u0131mlayan teklif sahiplerini nas\u0131l kar\u015f\u0131la\u015ft\u0131rabilir?<br \/>\n<strong>A:<\/strong> Her bir teklif sahibinden, sundu\u011fu malzeme tan\u0131mlay\u0131c\u0131s\u0131n\u0131, talepteki ayn\u0131 temas y\u00fczeyi girdisiyle e\u015fle\u015ftirmesini isteyin. Orijinal tan\u0131mlay\u0131c\u0131lar\u0131 g\u00f6r\u00fcn\u00fcr tutun; kar\u015f\u0131la\u015ft\u0131rma s\u0131ras\u0131nda, farkl\u0131 sunulan malzemeler, varsay\u0131lan bir e\u015fde\u011fer olarak yeniden adland\u0131r\u0131lmamal\u0131d\u0131r.<\/p>\n<p><strong>Q:<\/strong> Ya temizlik form\u00fclasyonu a\u00e7\u0131k ihale yoluyla g\u00f6nderilemezse?<br \/>\n<strong>A:<\/strong> Kararla\u015ft\u0131r\u0131lm\u0131\u015f, kontroll\u00fc bir referans ve bilgi payla\u015f\u0131m yolunu kullan\u0131n ve tedarik\u00e7inin gerekli bilgileri temin edene kadar ilgili cevab\u0131 \u201cko\u015fullu\u201d olarak i\u015faretleyin. Yaln\u0131zca ihale formunu doldurmak amac\u0131yla isimsiz, genel bir temsilciyi kullanmay\u0131n.<\/p>\n<p><strong>Q:<\/strong> Tek bir yan\u0131tlanmam\u0131\u015f soru, ticari kar\u015f\u0131la\u015ft\u0131rman\u0131n tamam\u0131n\u0131 kapsayabilir mi?<br \/>\n<strong>A:<\/strong> Cevaplanmam\u0131\u015f kombinasyonu ve bunun etkiledi\u011fi karar\u0131 g\u00f6r\u00fcn\u00fcr tutun. Etkilenmeyen fiyatland\u0131r\u0131lm\u0131\u015f kapsamlar yine de kar\u015f\u0131la\u015ft\u0131r\u0131labilir; ancak \u00e7\u00f6z\u00fclmemi\u015f uyumluluk gereklili\u011fini \u201ckar\u015f\u0131lanm\u0131\u015f\u201d olarak s\u0131n\u0131fland\u0131rmay\u0131n ya da bunu genel bir yan\u0131t\u0131n i\u00e7ine sessizce dahil etmeyin.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00d6nerilen temizlik maddeleri, temas y\u00fczeyleri ve sunulan malzemelere ili\u015fkin tedarik\u00e7i belgelerini kullanarak bir ge\u00e7i\u015f kutusu contas\u0131 uyumluluk incelemesi haz\u0131rlay\u0131n.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"n8n_meta_description":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-8590","post","type-post","status-publish","format-standard","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/8590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/comments?post=8590"}],"version-history":[{"count":1,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/8590\/revisions"}],"predecessor-version":[{"id":8591,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/8590\/revisions\/8591"}],"wp:attachment":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/media?parent=8590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/categories?post=8590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/tags?post=8590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}