{"id":7975,"date":"2026-11-16T05:32:19","date_gmt":"2026-11-15T21:32:19","guid":{"rendered":"https:\/\/qualia-bio.com\/blog\/single-vs-double-in-situ-hepa-set-the-project-basis\/"},"modified":"2026-11-16T05:32:19","modified_gmt":"2026-11-15T21:32:19","slug":"single-vs-double-in-situ-hepa-set-the-project-basis","status":"publish","type":"post","link":"https:\/\/qualia-bio.com\/tr\/blog\/single-vs-double-in-situ-hepa-set-the-project-basis\/","title":{"rendered":"Tekli ve \u00c7iftli Yerinde HEPA: Proje Temelini Belirleyin"},"content":{"rendered":"<p>Tehlikeli ila\u00e7 at\u0131k gazlar\u0131 i\u00e7in, tehlike de\u011ferlendirmesi ve projenin tasar\u0131m esaslar\u0131 izin verdi\u011fi her durumda tek bir son HEPA filtre grubu temel senaryo olarak kabul edilir; \u00f6zellikle tehlikeli bir de\u015farj\u0131n sonu\u00e7lar\u0131n\u0131n ek bir filtreleme a\u015famas\u0131n\u0131 hakl\u0131 k\u0131ld\u0131\u011f\u0131 durumlarda ise, seri olarak ba\u011flanan ikinci filtre grubu ko\u015fullu bir ekleme olarak de\u011ferlendirilir. <a href=\"https:\/\/cdn.who.int\/media\/docs\/default-source\/medicines\/norms-and-standards\/guidelines\/production\/trs957_annex3_who-gmp-for-pharmaceutical-products-containing-hazardous-substances.pdf\">Tehlikeli maddeler i\u00e7eren farmas\u00f6tik \u00fcr\u00fcnlere ili\u015fkin DS\u00d6 GMP k\u0131lavuzu<\/a> iki HEPA grubunu seri olarak, sabit bir gereklilik olarak de\u011fil, tam da bu anlamda ko\u015fullu bir unsur olarak ele al\u0131r. Proje temeli a\u00e7\u0131s\u0131ndan pratik sonu\u00e7 \u015fudur: Tekli mi yoksa \u00c7iftli Yerinde HEPA m\u0131 se\u00e7imi, \u00f6ncelikle egzoz sonu\u00e7lar\u0131na g\u00f6re belirlenir ve ancak bundan sonra diren\u00e7, izleme ve servis eri\u015fimi kriterlerine g\u00f6re belirlenir \u2014 ancak erken a\u015famada netle\u015ftirilmesi gereken bir istisna vard\u0131r: E\u011fer ge\u00e7erli proje kriterleri zaten iki grubu \u00f6ng\u00f6r\u00fcyorsa, iki grup temel al\u0131n\u0131r ve a\u00e7\u0131k kalan sorular bunlar\u0131n nas\u0131l kurulaca\u011f\u0131, izlenece\u011fi ve test edilece\u011fi ile ilgilidir.<\/p>\n<h2 id=\"setthehazardbasisforoneortwofinalhepabanks\">Bir veya iki adet son HEPA grubu i\u00e7in tehlike temelini belirleyin<\/h2>\n<table>\n<thead>\n<tr>\n<th>Proje temeli<\/th>\n<th>De\u011ferlendirilecek yap\u0131land\u0131rma<\/th>\n<th>Tasar\u0131m incelemesine neler getirilmeli<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Risk de\u011ferlendirmesi ve tasar\u0131m esaslar\u0131 kapsam\u0131nda son bir banka izin verilmektedir<\/td>\n<td>Tek bir son HEPA grubu<\/td>\n<td>\u00c7al\u0131\u015fma hava ak\u0131\u015f\u0131nda y\u00fckl\u00fc direnci ve s\u00f6z konusu blok i\u00e7in monte edilmi\u015f test eri\u015fim noktas\u0131n\u0131 do\u011frulay\u0131n<\/td>\n<\/tr>\n<tr>\n<td>\u00d6zellikle tehlikeli ila\u00e7 at\u0131klar\u0131, ek bir filtreleme a\u015famas\u0131n\u0131 gerektirir ya da proje kriterleri iki a\u015famal\u0131 filtrelemeyi \u015fart ko\u015far<\/td>\n<td>Seri ba\u011flanm\u0131\u015f iki HEPA grubu<\/td>\n<td>Toplam y\u00fck direncini kar\u015f\u0131la\u015ft\u0131r\u0131n ve her bir gerekli sonu\u00e7 i\u00e7in izleme ve test s\u0131n\u0131rlar\u0131n\u0131 belirleyin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Filtre grubu say\u0131s\u0131, bir filtreleme a\u015famas\u0131n\u0131n performans\u0131n\u0131n yetersiz kalmas\u0131 durumunda y\u0131\u011f\u0131ndan neyin \u00e7\u0131kt\u0131\u011f\u0131na g\u00f6re belirlenir; giren havan\u0131n ne kadar kirli oldu\u011funa g\u00f6re de\u011fil. Tehlike de\u011ferlendirmesi ve ge\u00e7erli tasar\u0131m esaslar\u0131 izin verdi\u011fi durumlarda, tek bir son filtre grubunu temel se\u00e7enek olarak fiyatland\u0131r\u0131n; de\u015farj\u0131n sonu\u00e7lar\u0131n\u0131n ikinci bir filtreleme a\u015famas\u0131n\u0131 gerektirecek kadar ciddi oldu\u011fu durumlarda ise seri se\u00e7ene\u011fini fiyatland\u0131r\u0131lm\u0131\u015f bir alternatif olarak sunun. Bu, tasar\u0131m incelemesine al\u0131\u015fkanl\u0131kla se\u00e7ilmi\u015f bir konfig\u00fcrasyon yerine ger\u00e7ek bir kar\u015f\u0131la\u015ft\u0131rma imk\u00e2n\u0131 sa\u011flar.<\/p>\n<p>\u0130\u015flevsel olarak, bu iki d\u00fczenleme, tek bir a\u015famadaki ar\u0131zan\u0131n ne anlama geldi\u011fi konusunda farkl\u0131l\u0131k g\u00f6sterir. Tek bir bankada, o bankaya monte edilmi\u015f s\u0131z\u0131nt\u0131 testi, proses havas\u0131 ile tahliye noktas\u0131 aras\u0131ndaki tek bariyerdir; dolay\u0131s\u0131yla bu testin b\u00fct\u00fcnl\u00fck sonucu, karar\u0131n tamam\u0131n\u0131 belirler. Seri ba\u011fl\u0131 iki bankada ise ayn\u0131 hava ak\u0131m\u0131na iki kez filtreleme uygulan\u0131r; bu sayede bir kademedeki bir ar\u0131za, di\u011fer kademenin filtreleme sistemi taraf\u0131ndan k\u0131smen telafi edilir \u2014 ancak bunun bedeli olarak ikinci bir diren\u00e7 seti, ikinci bir izleme s\u0131n\u0131r\u0131 ve ikinci bir test eri\u015fim gereksinimi ortaya \u00e7\u0131kar.<\/p>\n<p>Proje kriterleri say\u0131y\u0131 zaten iki olarak belirlemi\u015fse, m\u00fchendislik \u00e7al\u0131\u015fmalar\u0131 kurulum detaylar\u0131na y\u00f6nelir: her bir grubun kendi bas\u0131n\u00e7 g\u00f6stergesine sahip olup olmad\u0131\u011f\u0131, her birinin kurulum halindeyken s\u0131z\u0131nt\u0131 testine tabi tutulup tutulamayaca\u011f\u0131 ve muhafazalar\u0131n, projenin bak\u0131m yakla\u015f\u0131m\u0131yla uyumlu \u015fekilde filtrelerin g\u00fcvenli bir \u015fekilde de\u011fi\u015ftirilmesine izin verip vermedi\u011fi. Bu detaylar, ikinci grubun do\u011frulanabilir bir a\u015fama m\u0131 yoksa sadece ek bir bas\u0131n\u00e7 d\u00fc\u015f\u00fc\u015f\u00fc m\u00fc oldu\u011funu belirler.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"separatedischargeprotectionfromdustloadingandservicecontinuity\">Toz birikmesine kar\u015f\u0131 koruma ile hizmet s\u00fcreklili\u011fini birbirinden ay\u0131rma<\/h2>\n<p>\u00dc\u00e7 farkl\u0131 sorun, \u00fc\u00e7 farkl\u0131 ekipmanla \u00e7\u00f6z\u00fcl\u00fcr ve bunlar\u0131n birbirine kar\u0131\u015ft\u0131r\u0131lmas\u0131, projelerin kimsenin gerek\u00e7elendiremeyece\u011fi bir konfig\u00fcrasyonla sonu\u00e7lanmas\u0131na neden olur. \u0130kinci bir HEPA grubu, devreye seri olarak bir filtreleme a\u015famas\u0131 ekler. Ak\u0131\u015f y\u00f6n\u00fcnde yer alan \u00f6n filtreleme, ilk HEPA grubunu partik\u00fcl y\u00fck\u00fcnden korur. Varsa, ayr\u0131 olarak izole edilebilen bir yol, bir grup hizmet d\u0131\u015f\u0131 kald\u0131\u011f\u0131nda egzoz sisteminin \u00e7al\u0131\u015fmaya devam etmesini sa\u011flar. Bu \u00fc\u00e7\u00fcnden hi\u00e7biri, di\u011ferlerinin yerine ge\u00e7mez.<\/p>\n<p>\u0130kinci filtre grubunun eklenmesi i\u00e7in belirtilen neden, tozlu \u00e7al\u0131\u015fma ko\u015fullar\u0131nda ilk grubun \u00e7ok h\u0131zl\u0131 t\u0131kanmas\u0131 ise, bunu bir \u00f6n filtreleme ve toz kayna\u011f\u0131 sorunu olarak de\u011ferlendirin ve ayr\u0131 bir \u015fekilde \u00e7\u00f6z\u00fcn. Tehlikeli madde \u00fcretimine ili\u015fkin WHO k\u0131lavuzunda, tozlu hava i\u00e7in \u00f6n filtrelerin kullan\u0131lmas\u0131 tam da t\u0131kanman\u0131n bir t\u0131kanma sorunu olmas\u0131 nedeniyle a\u00e7\u0131k\u00e7a belirtilmi\u015ftir. \u00d6n filtre d\u00fczenini de\u011fi\u015ftirin veya kayna\u011f\u0131nda toz ta\u015f\u0131nmas\u0131n\u0131 azalt\u0131n, ard\u0131ndan HEPA a\u015fama say\u0131s\u0131n\u0131 de\u015farj riskine g\u00f6re belirleyin. Bu ikisini kar\u0131\u015ft\u0131rmak, eklenen direncin amac\u0131n\u0131 belirsizle\u015ftirir: \u0130kinci filtre grubu, y\u00fckleme tamponu olarak de\u011fil, filtreleme amac\u0131yla sat\u0131n al\u0131n\u0131r ve bunu y\u00fckleme ba\u015fl\u0131\u011f\u0131 alt\u0131nda g\u00f6ren bir denet\u00e7i, bunun neyi ba\u015farmay\u0131 ama\u00e7lad\u0131\u011f\u0131n\u0131 anlayamaz.<\/p>\n<p>Hizmet s\u00fcreklili\u011fi, \u00fc\u00e7\u00fcnc\u00fc ve ayr\u0131 bir kontrol unsurudur. Seri ba\u011fl\u0131 iki a\u015fama normalde ayn\u0131 hava ak\u0131\u015f g\u00fczerg\u00e2h\u0131nda yer al\u0131r; dolay\u0131s\u0131yla bunlardan herhangi birinin devre d\u0131\u015f\u0131 b\u0131rak\u0131lmas\u0131, ayn\u0131 g\u00fczerg\u00e2h\u0131n kesintiye u\u011framas\u0131na neden olur. Filtre grubu izole edildi\u011finde egzozun \u00e7al\u0131\u015fmaya devam etmesi gerekiyorsa, ayr\u0131 olarak izole edilebilen g\u00fczerg\u00e2h\u0131 ve sistemin bu durumda s\u00fcrd\u00fcrebilece\u011fi bas\u0131n\u00e7 ili\u015fkisini g\u00f6steren bir hizmet durumu hava ak\u0131\u015f \u015femas\u0131 talep edin. Yaln\u0131zca normal \u00e7al\u0131\u015fma durumunu g\u00f6steren bir \u015fema soruyu yan\u0131tlamaz; \u00e7\u00fcnk\u00fc ilgili durum, bir grubun vanayla devre d\u0131\u015f\u0131 b\u0131rak\u0131ld\u0131\u011f\u0131 durumdur. Belirli bir servis durumunun hizmet verdi\u011fi oda i\u00e7in kabul edilebilir olup olmad\u0131\u011f\u0131, konfig\u00fcrasyon \u00e7iziminin kendi ba\u015f\u0131na belirleyebilece\u011fi bir konu de\u011fil, projenin onaylanm\u0131\u015f prosed\u00fcr\u00fc ve atanm\u0131\u015f onaylay\u0131c\u0131s\u0131 taraf\u0131ndan verilecek bir karard\u0131r.<\/p>\n<h2 id=\"compareresistanceoverthesameoperatingrange\">Ayn\u0131 \u00e7al\u0131\u015fma aral\u0131\u011f\u0131 i\u00e7indeki diren\u00e7leri kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h2>\n<p>Ayn\u0131 tasar\u0131m hava ak\u0131\u015f\u0131n\u0131 belirten iki teklif, diren\u00e7 de\u011ferleri ayn\u0131 bo\u015f ve y\u00fckl\u00fc \u00e7al\u0131\u015fma ko\u015fullar\u0131na g\u00f6re hesaplanmad\u0131k\u00e7a kar\u015f\u0131la\u015ft\u0131r\u0131lamaz. Seri kademeler diren\u00e7 ekledi\u011finden, \u00e7ift s\u0131ral\u0131 bir d\u00fczenleme, benzer filtre malzemeleri \u00fczerinden ayn\u0131 hava hacmini ta\u015f\u0131yan tek s\u0131ral\u0131 bir d\u00fczenlemeye k\u0131yasla fan\u0131n daha fazla performans g\u00f6stermesini ka\u00e7\u0131n\u0131lmaz olarak gerektirir. As\u0131l mesele, direncin art\u0131p artmad\u0131\u011f\u0131 de\u011fil, fan se\u00e7iminin planlanan servis aral\u0131\u011f\u0131n\u0131n sonunda hala gerekli hava ak\u0131\u015f\u0131n\u0131 sa\u011flay\u0131p sa\u011flamayaca\u011f\u0131d\u0131r.<\/p>\n<p>Temiz filtre bas\u0131n\u00e7 de\u011feri, belirtilmesi en kolay rakam olmakla birlikte boyutland\u0131rma a\u00e7\u0131s\u0131ndan en az yararl\u0131 oland\u0131r. Filtreler dolduk\u00e7a diren\u00e7 kazan\u0131r ve sistemin s\u00fcrd\u00fcrmesi gereken hava ak\u0131\u015f\u0131, ilk \u00e7al\u0131\u015ft\u0131rma an\u0131ndaki de\u011fil, dolmu\u015f durumdaki hava ak\u0131\u015f\u0131d\u0131r. Her iki tedarik\u00e7iden de kulland\u0131klar\u0131 y\u00fckl\u00fc diren\u00e7 temelini (her a\u015fama i\u00e7in varsayd\u0131klar\u0131 de\u011fi\u015ftirme fark\u0131n\u0131) belirtmelerini isteyin ve \u00f6n filtreler, damperler, kanal sistemi tolerans\u0131 ve muhafaza g\u00f6vdesi dahil olmak \u00fczere, \u00fczerinde anla\u015f\u0131lan bu temele g\u00f6re toplam yol direncini kar\u015f\u0131la\u015ft\u0131r\u0131n. \u0130ki teklif farkl\u0131 y\u00fckleme toleranslar\u0131 varsaym\u0131\u015fsa, aralar\u0131ndaki ba\u015fl\u0131k bas\u0131n\u00e7 fark\u0131 k\u0131smen bir varsay\u0131m fark\u0131d\u0131r, ekipman fark\u0131 de\u011fildir.<\/p>\n<p>Ard\u0131ndan, s\u00f6z konusu y\u00fck ko\u015fulunda gerekli hava ak\u0131\u015f\u0131 seviyesinde fan marj\u0131n\u0131 a\u00e7\u0131k\u00e7a kontrol edin. Temiz filtreler kullan\u0131ld\u0131\u011f\u0131nda rahat bir marjla boyutland\u0131r\u0131lm\u0131\u015f bir fan, iki HEPA grubu de\u011fi\u015ftirilme zaman\u0131na yakla\u015ft\u0131\u011f\u0131nda s\u0131n\u0131r\u0131na yakla\u015fabilir; bu durumun ilk belirtisi, her \u015fey h\u00e2l\u00e2 \u00e7al\u0131\u015f\u0131yor gibi g\u00f6r\u00fcn\u00fcrken hava ak\u0131\u015f\u0131n\u0131n tasar\u0131m de\u011ferinin alt\u0131na d\u00fc\u015fmesidir. \u0130zolasyon havaland\u0131rmas\u0131nda, hava ak\u0131\u015f\u0131ndaki d\u00fc\u015f\u00fc\u015f odan\u0131n dayand\u0131\u011f\u0131 bas\u0131n\u00e7 ili\u015fkilerini de\u011fi\u015ftirir; bu nedenle marj konusu, devreye alma a\u015famas\u0131ndan ziyade teknik kar\u015f\u0131la\u015ft\u0131rma kapsam\u0131nda ele al\u0131nmal\u0131d\u0131r.<\/p>\n<p>\u00d6rnek bir kar\u015f\u0131la\u015ft\u0131rma olarak, ayn\u0131 kanal hatt\u0131 ve ayn\u0131 \u00e7al\u0131\u015fma hava ak\u0131\u015f\u0131 i\u00e7in iki teklif oldu\u011funu varsayal\u0131m: biri \u00f6n filtre ve tek bir son HEPA grubu i\u00e7eren, di\u011feri ise \u00f6n filtre ve seri ba\u011flanm\u0131\u015f iki HEPA grubu i\u00e7eren. Her iki teklif de sadece temiz hava bas\u0131n\u00e7 d\u00fc\u015f\u00fc\u015f\u00fcn\u00fc belirtirse, ikincisi biraz daha k\u00f6t\u00fc g\u00f6r\u00fcn\u00fcr. Her iki teklif de her a\u015fama i\u00e7in \u00fczerinde anla\u015fmaya var\u0131lan bir y\u00fckleme ko\u015fulu temelinde yeniden hesaplan\u0131rsa, aradaki fark artar; \u00e7\u00fcnk\u00fc her HEPA a\u015famas\u0131 kendi y\u00fckleme pay\u0131n\u0131 katar. Buradaki varsay\u0131mlar \u00f6l\u00e7\u00fclm\u00fc\u015f de\u011fil, ifade edilmi\u015ftir; as\u0131l mesele, y\u00fckleme esaslar\u0131 ortak hale getirildi\u011finde teklifler aras\u0131ndaki s\u0131ralaman\u0131n de\u011fi\u015febilece\u011fidir.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"checkwhatcanbemeasuredandtestedateachbank\">Her bir bankada nelerin \u00f6l\u00e7\u00fclebilece\u011fini ve test edilebilece\u011fini kontrol edin<\/h2>\n<p>\u00c7ift s\u0131ral\u0131 bir filtre grubu, ancak her bir s\u0131ra ayr\u0131 bir s\u0131n\u0131r olarak izlenip test edilebiliyorsa pratikte iki a\u015famal\u0131 bir tasar\u0131md\u0131r. DS\u00d6\u2019n\u00fcn tehlikeli maddelerle ilgili k\u0131lavuzunda, filtre s\u0131ralar\u0131 genelinde bas\u0131n\u00e7 izleme ve kurulu test eri\u015fim noktalar\u0131 d\u00fczenlemenin bir par\u00e7as\u0131 olarak tan\u0131mlanmaktad\u0131r; bu nedenle, bir teklif de\u011ferlendirilirken dikkate al\u0131nmas\u0131 gereken \u00f6nemli soru, her bir eri\u015fim noktas\u0131n\u0131n ve her bir g\u00f6stergenin fiilen hangi fiziksel sonucu ortaya koydu\u011fudur.<\/p>\n<p>\u00c7ift s\u0131ral\u0131 bir sistemde tek bir bas\u0131n\u00e7 g\u00f6stergesi bulunuyorsa, bu de\u011fer her iki kademenin direncini birle\u015ftirir. Toplam direncin ne zaman artt\u0131\u011f\u0131n\u0131 g\u00f6steren bu birle\u015fik de\u011fer, planlama a\u00e7\u0131s\u0131ndan yararl\u0131d\u0131r; ancak hangi s\u0131ran\u0131n y\u00fckl\u00fc oldu\u011funu veya bir kademenin baypas olup olmad\u0131\u011f\u0131n\u0131 g\u00f6stermez. Projede, tek tek s\u0131ralar\u0131n ne zaman de\u011fi\u015ftirilmesi gerekti\u011fini bilmek gerekiyorsa, her s\u0131ran\u0131n kendi diferansiyel g\u00f6stergesine sahip olmas\u0131 gerekir; bu, bir varsay\u0131m de\u011fil, maliyeti olan bir teknik \u015fartt\u0131r.<\/p>\n<p>Ayn\u0131 durum, kurulu sistemlerde yap\u0131lan s\u0131z\u0131nt\u0131 testleri i\u00e7in de ge\u00e7erlidir. Tarama veya zorlama testleri, test edilen bankan\u0131n ak\u0131\u015f y\u00f6n\u00fcnde bir enjeksiyon noktas\u0131na ve bunun ak\u0131\u015f y\u00f6n\u00fcn\u00fcn a\u015fa\u011f\u0131s\u0131nda, muhafaza geometrisinin i\u00e7inde bir eri\u015fim noktas\u0131na ihtiya\u00e7 duyar. Eri\u015fimin yaln\u0131zca muhafazan\u0131n d\u0131\u015f\u0131ndan sa\u011flanmas\u0131 durumunda her iki banka da tek bir test s\u0131n\u0131r\u0131 i\u00e7inde kalabilir; bu durumda y\u00f6ntem, birle\u015fik s\u0131n\u0131r\u0131 do\u011frular ve birinci bankadaki bir ar\u0131zay\u0131 ikinci bankadakinden ay\u0131rt edemez. Tedarik\u00e7iden, her bir okuma de\u011ferini ve kurulu her test konumunu temsil etti\u011fi belirli bankaya veya birle\u015fik s\u0131n\u0131ra e\u015fle\u015ftirmesini ve projenin gerektirdi\u011fi ek eri\u015fimlerin fiyat\u0131n\u0131 ayr\u0131 bir sat\u0131r olarak belirtmesini isteyin.<\/p>\n<p>Bu \u015fema, bak\u0131m i\u015flemlerini de \u015fekillendirir. \u201cBag-in\/bag-out\u201d muhafazas\u0131 arac\u0131l\u0131\u011f\u0131yla g\u00fcvenli filtre de\u011fi\u015fimi, bir filtre grubunun izole edilme s\u0131ras\u0131 ve yukar\u0131 ak\u0131\u015ftaki de\u011fi\u015fim s\u0131ras\u0131nda a\u015fa\u011f\u0131 ak\u0131\u015ftaki filtre grubunun korunup korunmayaca\u011f\u0131 gibi sorular\u0131n t\u00fcm\u00fcne ayn\u0131 \u00e7izim cevap vermelidir. Kurulmu\u015f herhangi bir test sonucunun kabul\u00fc ve filtre de\u011fi\u015fimi sonras\u0131nda bir filtre grubunun hizmete geri al\u0131nmas\u0131, projenin onaylanm\u0131\u015f prosed\u00fcr\u00fc ve bu prosed\u00fcrde belirtilen onaylay\u0131c\u0131 taraf\u0131ndan d\u00fczenlenir.<\/p>\n<h2 id=\"reviewbiosafetylaboratoryexhaustonitsowndesignbasis\">Biyog\u00fcvenlik laboratuvar\u0131 egzoz sistemini kendi tasar\u0131m esaslar\u0131 \u00e7er\u00e7evesinde g\u00f6zden ge\u00e7irin<\/h2>\n<p>Biyog\u00fcvenlik laboratuvar\u0131 egzoz sistemi, tehlikeli ila\u00e7 \u00fcretimindeki konfig\u00fcrasyon mant\u0131\u011f\u0131n\u0131 benimsemez; bu iki sistem aras\u0131nda ticari bir d\u00fczenlemenin aktar\u0131lmas\u0131, projelerin kimsenin izini s\u00fcremeyece\u011fi gereksinimlere yol a\u00e7ar. WHO\u2019nun seri ba\u011fl\u0131 iki HEPA filtresine ili\u015fkin \u015fart\u0131, tehlikeli maddelerin ila\u00e7 \u00fcretiminde ge\u00e7erlidir. Bu <a href=\"https:\/\/www.cdc.gov\/labs\/media\/pdfs\/2025\/08\/SF__19a_308133-A_BMBL6_00-BOOK-WEB-final-3.pdf\">CDC\/NIH BMBL<\/a> Belirli BSL-3 birincil bariyerli egzoz sistemleri i\u00e7in HEPA veya e\u015fde\u011fer filtreleme ve filtre testlerini a\u00e7\u0131klamaktad\u0131r; bu, s\u00f6z konusu birincil bariyer ba\u011flam\u0131yla s\u0131n\u0131rl\u0131 bir tavsiye niteli\u011finde bir k\u0131lavuzdur ve laboratuvar egzoz a\u015famalar\u0131n\u0131n say\u0131s\u0131 hakk\u0131nda genel bir a\u00e7\u0131klama de\u011fildir.<\/p>\n<p>Dolay\u0131s\u0131yla, bir laboratuvar projesi i\u00e7in, herhangi bir konfig\u00fcrasyon uygulanmadan \u00f6nce \u00fc\u00e7 hususu netle\u015ftirin: s\u00f6z konusu egzoz ak\u0131\u015f\u0131n\u0131n hangisi oldu\u011fu \u2014 bir kabin veya izolat\u00f6rden gelen birincil bariyer egzozu mu, yoksa genel oda egzozu mu; filtrelemenin hangi muhafaza senaryosuna kar\u015f\u0131 koruma sa\u011flad\u0131\u011f\u0131 (buna, filtre de\u011fi\u015fimi s\u0131ras\u0131nda oda bas\u0131n\u00e7 ili\u015fkilerinin nas\u0131l olmas\u0131 gerekti\u011fi de dahildir); ve tesise hangi kriterlerin fiilen uyguland\u0131\u011f\u0131 (biyog\u00fcvenlik k\u0131lavuzu, ulusal bir gereklilik ya da d\u00fczenlemeyi halihaz\u0131rda belirleyen bir m\u00fc\u015fteri \u015fartnamesi olabilir). Ancak o zaman \u201cbanka say\u0131s\u0131\u201d sorusu yan\u0131tlanabilir hale gelir ve bu yan\u0131t, diren\u00e7le hi\u00e7bir ilgisi olmayan nedenlerden \u00f6t\u00fcr\u00fc ila\u00e7 sekt\u00f6r\u00fcndeki durumdan farkl\u0131 olabilir.<\/p>\n<p>D\u00fczenleme belirlendikten sonra, bunun yine de ayr\u0131 ve do\u011frulanabilir denetimlere d\u00f6n\u00fc\u015ft\u00fcr\u00fclmesi gerekir: <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/hepa-exhaust-acceptance-criteria-for-bsl-3-4-labs-filter-integrity-duct-leakage-and-bibo-maintenance-access\/\">tan\u0131mlanm\u0131\u015f her s\u0131n\u0131rda filtre b\u00fct\u00fcnl\u00fc\u011f\u00fc testi<\/a>, muhafaza kanal sisteminin s\u0131z\u0131nt\u0131 testi ve \u201cbag-in\/bag-out\u201d muhafazalar\u0131 arac\u0131l\u0131\u011f\u0131yla g\u00fcvenli filtre de\u011fi\u015fimi i\u00e7in fiziksel eri\u015fim. Bunlar, farkl\u0131 y\u00f6ntemler ve farkl\u0131 kan\u0131tlara dayanan \u00fc\u00e7 ayr\u0131 kabul i\u015flemidir; bunlardan birini kar\u015f\u0131layan bir d\u00fczenleme, di\u011ferini engelleyebilir \u2014 s\u0131z\u0131nt\u0131 testini ge\u00e7en bir muhafaza, yine de de\u011fi\u015ftirme torbas\u0131n\u0131 kullanmaya imkan vermeyebilir.<\/p>\n<p>Bir tedarik\u00e7iyle \u015fu konu hakk\u0131nda verimli bir g\u00f6r\u00fc\u015fme yapmak i\u00e7in <a href=\"https:\/\/qualia-bio.com\/tr\/product\/airseriers\/in-situ-filtration-system\/\">yerinde filtreleme muhafazalar\u0131<\/a>, egzoz ak\u0131\u015f\u0131n\u0131 ve bunun tehlike temelini, kullanmay\u0131 planlad\u0131\u011f\u0131n\u0131z y\u00fck direnci pay\u0131 dahilinde \u00e7al\u0131\u015fma hava ak\u0131\u015f\u0131n\u0131, normal \u00e7al\u0131\u015fma s\u0131ras\u0131nda ve bir blok izolasyonu s\u0131ras\u0131nda korunmas\u0131 gereken oda bas\u0131n\u00e7 ili\u015fkilerini ve projenin her bir blokta gerektirece\u011fi kurulu testlerin ve uygunluk kan\u0131tlar\u0131n\u0131n listesini belirleyin. Bunlar elinizde oldu\u011funda, size geri g\u00f6nderilen \u00e7izim, genel bir yerle\u015fim plan\u0131 yerine tasar\u0131m temeli ile kar\u015f\u0131la\u015ft\u0131r\u0131larak kontrol edilebilir.<\/p>\n<h2 id=\"frequentlyaskedquestions\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<p><strong>Q:<\/strong> Tasar\u0131m esaslar\u0131 kesinle\u015fmeden \u00f6nce ikinci banka i\u00e7in fiyat teklifi alabilir miyim?<br \/>\n<strong>A:<\/strong> Evet, \u015fartl\u0131 bir alternatif olarak. Her iki teklife de ayn\u0131 g\u00f6revi verin ve teklif sahibinden, ayak izi, diren\u00e7 ve test d\u00fczenlemesindeki de\u011fi\u015fiklikleri g\u00f6stermesini isteyin; b\u00f6ylece tehlike temeli gerektirdi\u011fi takdirde bu alternatifi de\u011ferlendirebilirsiniz.<\/p>\n<p><strong>Q:<\/strong> \u0130kinci bir son kontrol, her iki filtrenin de ayn\u0131 anda de\u011fi\u015ftirilmesi gerekti\u011fi anlam\u0131na m\u0131 gelir?<br \/>\n<strong>A:<\/strong> Hizmet kapsam\u0131n\u0131, her bir bankan\u0131n durumuna ve projenin izolasyon ve i\u015fleme d\u00fczenlemelerine g\u00f6re belirleyin. Bu iki filtre, her biri i\u00e7in ayn\u0131 hizmet kan\u0131t\u0131n\u0131 veya eri\u015fimi sa\u011flamadan tek bir yap\u0131 i\u00e7inde bir arada bulunabilir.<\/p>\n<p><strong>Q:<\/strong> Ya bir teklif sahibi toplam bas\u0131n\u00e7 d\u00fc\u015f\u00fc\u015f\u00fcn\u00fc belirtirse, di\u011feri ise her bir grubu ayr\u0131 ayr\u0131 bildirirse ne olur?<br \/>\n<strong>A:<\/strong> Her ikisinden de ayn\u0131 hava ak\u0131\u015f\u0131 ve y\u00fck ko\u015fullar\u0131nda ayn\u0131 tam yolu kapsayan verileri isteyin. Hizmet de\u011ferlendirmesi i\u00e7in banka d\u00fczeyindeki verileri ayr\u0131 tutun ve toplam baz de\u011ferini uyu\u015fturam\u0131yorsan\u0131z teklifi \u201c\u00e7\u00f6z\u00fclmemi\u015f\u201d olarak i\u015faretleyin.<\/p>","protected":false},"excerpt":{"rendered":"<p>Tekli ve \u00e7iftli yerinde HEPA gruplar\u0131n\u0131, tahliye riski, y\u00fckl\u00fc fan \u00e7al\u0131\u015fmas\u0131, test eri\u015fimi ve bak\u0131m s\u0131ras\u0131nda egzozun \u00e7al\u0131\u015f\u0131r durumda tutulmas\u0131 gereklili\u011fi a\u00e7\u0131s\u0131ndan kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"n8n_meta_description":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-7975","post","type-post","status-publish","format-standard","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/comments?post=7975"}],"version-history":[{"count":1,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7975\/revisions"}],"predecessor-version":[{"id":7976,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7975\/revisions\/7976"}],"wp:attachment":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/media?parent=7975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/categories?post=7975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/tags?post=7975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}