{"id":7971,"date":"2026-11-15T05:32:25","date_gmt":"2026-11-14T21:32:25","guid":{"rendered":"https:\/\/qualia-bio.com\/blog\/retrofitting-vacu-pass-around-existing-lab-cables\/"},"modified":"2026-11-15T05:32:26","modified_gmt":"2026-11-14T21:32:26","slug":"retrofitting-vacu-pass-around-existing-lab-cables","status":"publish","type":"post","link":"https:\/\/qualia-bio.com\/tr\/blog\/retrofitting-vacu-pass-around-existing-lab-cables\/","title":{"rendered":"Mevcut Laboratuvar Kablolar\u0131n\u0131n Etraf\u0131na Vacu-Pass'\u0131n Sonradan Tak\u0131lmas\u0131"},"content":{"rendered":"<p>Bir []'nin yenilenmesi <a href=\"https:\/\/qualia-bio.com\/tr\/product\/lockseries\/vacu-pass-cord-and-cable-port\/\">Vacu-Pass kablosu ve kablo ba\u011flant\u0131 noktas\u0131<\/a> Zaten d\u00f6\u015fenmi\u015f kablolar\u0131n etraf\u0131ndan ge\u00e7i\u015f yapmak, \u00fc\u00e7 saha ko\u015fulu bir araya geldi\u011finde pratik bir \u00e7\u00f6z\u00fcmd\u00fcr: mevcut duvar a\u00e7\u0131kl\u0131\u011f\u0131 (veya yeni bir a\u00e7\u0131kl\u0131k), ba\u011flant\u0131 \u00e7er\u00e7evesinin ger\u00e7ek yal\u0131t\u0131m bariyerine s\u0131k\u0131ca oturacak \u015fekilde olu\u015fturulabilmeli, her bir kablonun k\u0131l\u0131f \u00e7ap\u0131 belgelenmi\u015f bir s\u0131zd\u0131rmazl\u0131k konumuyla e\u015fle\u015fmeli ve ya en b\u00fcy\u00fck konekt\u00f6r montajdan ge\u00e7ebilmeli ya da ba\u011flant\u0131 noktas\u0131, mevcut alanda bozulmam\u0131\u015f kablo g\u00fczerg\u00e2h\u0131n\u0131n etraf\u0131na in\u015fa edilebilmelidir. Bir kordon ve kablo ge\u00e7idi, oda s\u0131n\u0131r\u0131n\u0131 kesintisiz tutarken kablolar\u0131 bu s\u0131n\u0131rdan ge\u00e7iren s\u0131zd\u0131rmaz ge\u00e7i\u015f d\u00fczene\u011fidir. Bu \u00fc\u00e7 ko\u015fulun herhangi biri kar\u015f\u0131lanmad\u0131\u011f\u0131nda \u2014 hasarl\u0131 bir man\u015fon, montaj i\u00e7in \u00e7ok b\u00fcy\u00fck bir kal\u0131pl\u0131 t\u0131pa, hizmetten \u00e7\u0131kar\u0131lamayan bir kablo \u2014 yenileme \u00e7al\u0131\u015fmas\u0131 durdurulmak yerine \u015fekil de\u011fi\u015ftirir; bu genellikle kablonun g\u00fczerg\u00e2h\u0131n\u0131n yeniden belirlenmesiyle veya bariyere ba\u011flanabilen bir ge\u00e7i\u015f noktas\u0131nda farkl\u0131 bir belgelenmi\u015f montaj\u0131n se\u00e7ilmesiyle sa\u011flan\u0131r.<\/p>\n<h2 id=\"checkwhethertheexistingwallopeningcanbereused\">Mevcut duvar a\u00e7\u0131kl\u0131\u011f\u0131n\u0131n yeniden kullan\u0131labilir olup olmad\u0131\u011f\u0131n\u0131 kontrol edin<\/h2>\n<p>\u00d6l\u00e7\u00fcm\u00fc kablodan de\u011fil duvardan ba\u015flat\u0131n; \u00e7\u00fcnk\u00fc yeniden kullan\u0131m, ancak yenileme \u00e7al\u0131\u015fmas\u0131 tam olarak o noktada bariyere s\u0131zd\u0131rmaz bir \u015fekilde birle\u015ftirilebiliyorsa anlaml\u0131d\u0131r. A\u00e7\u0131kl\u0131\u011f\u0131n net boyutlar\u0131n\u0131, duvar yap\u0131s\u0131n\u0131 ve man\u015fon detaylar\u0131n\u0131, mevcut s\u0131zd\u0131rmazl\u0131k eleman\u0131n\u0131n veya man\u015fonun durumunu ve hem muhafaza taraf\u0131 hem de hizmet taraf\u0131 \u00fczerinden mevcut \u00e7al\u0131\u015fma eri\u015fimini kaydedin. \u00d6nerilen ba\u011flant\u0131 noktas\u0131 \u00e7iziminin bu d\u00f6rt ayr\u0131nt\u0131yla uyumlu olmas\u0131 gerekir.<\/p>\n<p>Uyum, sadece \u00e7apla s\u0131n\u0131rl\u0131 de\u011fildir. Ba\u011flant\u0131 \u00e7er\u00e7evesi, bariyerin bir par\u00e7as\u0131 olan ve \u00e7er\u00e7eveyi ve duvarla temas eden contas\u0131n\u0131 bar\u0131nd\u0131racak kadar d\u00fcz bir dayanak alan\u0131na ve yeterli derinli\u011fe sahip bir y\u00fczeye oturmal\u0131d\u0131r; k\u00f6p\u00fck dolgulu bir ge\u00e7i\u015f i\u00e7in d\u00f6k\u00fclm\u00fc\u015f bir man\u015fon, bu y\u00fczeyi sa\u011flamayabilir. Her iki taraftan eri\u015fim de ayn\u0131 derecede \u00f6nemlidir; \u00e7\u00fcnk\u00fc temiz taraftan ula\u015f\u0131lamayan bir \u00e7er\u00e7eve, o taraftan monte edilemez, s\u0131k\u0131la\u015ft\u0131r\u0131lamaz veya denetlenemez.<\/p>\n<p>Man\u015fon \u00e7atlam\u0131\u015f, a\u015f\u0131nm\u0131\u015f, duvarda gev\u015femi\u015fse ya da ba\u011flant\u0131 noktas\u0131 o noktada bariyere tam olarak uymuyorsa, zorla oturtmaya \u00e7al\u0131\u015fmak yerine tasar\u0131m incelemesine farkl\u0131 bir ge\u00e7i\u015f se\u00e7ene\u011fi sunun. Yeni bir a\u00e7\u0131kl\u0131k a\u00e7mak ek i\u015f gerektirir; ancak hasarl\u0131 bir man\u015fona s\u0131zd\u0131rmaz \u015fekilde ba\u011flanm\u0131\u015f bir ba\u011flant\u0131 noktas\u0131, kusuru bitmi\u015f s\u0131n\u0131r yap\u0131s\u0131na aktar\u0131r ve bu kusuru daha sonra tespit etmek, \u015fu anda \u00f6nlemekten daha zordur. <a href=\"https:\/\/www.efbs.admin.ch\/inhalte\/dokumentation\/empfehlungen\/Empfehlungen_aktuell\/Structural_and_Technical_Safety_Measures_BSL3_E.pdf\">\u0130svi\u00e7re Biyog\u00fcvenlik Uzman Komitesi\u2019nin BSL-3 laboratuvarlar\u0131ndaki yap\u0131sal ve teknik g\u00fcvenlik \u00f6nlemlerine ili\u015fkin tavsiyesi<\/a> kablo ge\u00e7i\u015flerini ve yedek ge\u00e7i\u015f a\u00e7\u0131kl\u0131klar\u0131n\u0131 fumigasyona uygun s\u0131n\u0131r\u0131n bir par\u00e7as\u0131 olarak de\u011ferlendirir; bu nedenle mevcut man\u015fonun durumu, estetik bir mesele de\u011fil, tasar\u0131mla ilgili bir konudur.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"decidewhichcablescanstayconnected\">Hangi kablolar\u0131n ba\u011fl\u0131 kalabilece\u011fine karar verin<\/h2>\n<table>\n<thead>\n<tr>\n<th>G\u00fczerg\u00e2h<\/th>\n<th>\u015eu durumlarda kullan\u0131n:<\/th>\n<th>Se\u00e7im yapmadan \u00f6nce kontrol edin<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kabloyu tak\u0131l\u0131 b\u0131rak\u0131n<\/td>\n<td>Bozulmam\u0131\u015f k\u0131s\u0131m\u0131n etraf\u0131na tam olarak uyan \u00e7er\u00e7eve ve conta tak\u0131labilir<\/td>\n<td>Conta k\u0131sm\u0131ndaki ceket \u00e7ap\u0131, sabit konekt\u00f6r konumu ve \u00e7al\u0131\u015fma alan\u0131<\/td>\n<\/tr>\n<tr>\n<td>Kabloyu \u00e7\u0131kar\u0131n ve i\u00e7inden ge\u00e7irin<\/td>\n<td>Planl\u0131 bir ba\u011flant\u0131 kesintisine izin verilir ve mevcut ge\u00e7i\u015f noktas\u0131 uygunlu\u011funu korur<\/td>\n<td>Montaj a\u00e7\u0131kl\u0131\u011f\u0131na g\u00f6re en geni\u015f konekt\u00f6r d\u0131\u015f hatlar\u0131 (k\u0131l\u0131f \u00e7ap\u0131ndan ba\u011f\u0131ms\u0131z olarak)<\/td>\n<\/tr>\n<tr>\n<td>Y\u00f6n\u00fc de\u011fi\u015ftirin veya farkl\u0131 bir montaj se\u00e7in<\/td>\n<td>Kablo \u00e7\u0131kar\u0131lamaz ve se\u00e7ilen montaj par\u00e7as\u0131 kablonun etraf\u0131na tak\u0131lamaz<\/td>\n<td>Bariyere ba\u011flanabilen, uygun bir ge\u00e7i\u015f noktas\u0131nda yap\u0131lm\u0131\u015f ve belgelenmi\u015f bir d\u00fczenleme<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Her kablo i\u00e7in, g\u00fczerg\u00e2h\u0131 belirleyen iki boyut vard\u0131r ve bunlar ayr\u0131 ayr\u0131 \u00f6l\u00e7\u00fcl\u00fcr: contan\u0131n kavrayaca\u011f\u0131 noktadaki k\u0131l\u0131f \u00e7ap\u0131 ve hat \u00fczerindeki en b\u00fcy\u00fck sabit konekt\u00f6r\u00fcn d\u0131\u015f hatlar\u0131. Kal\u0131planm\u0131\u015f bir cihaz fi\u015fi, \u00fcst\u00fc kal\u0131planm\u0131\u015f bir M12 konekt\u00f6r\u00fc, k\u0131vr\u0131ml\u0131 \u00e7ok pimli bir k\u0131l\u0131f \u2014 her birini sabit sonland\u0131rma olarak listeleyin ve \u00f6nerilen montajdan ge\u00e7ip ge\u00e7emeyece\u011fini i\u015faretleyin. 9 mm'lik bir k\u0131l\u0131f i\u00e7in yeterince geni\u015f bir a\u00e7\u0131kl\u0131k, geni\u015fli\u011fi bunun iki kat\u0131 olan kal\u0131planm\u0131\u015f bir fi\u015fi yine de ge\u00e7irmeyebilir ve bu tek ger\u00e7ek, kablonun i\u00e7inden ge\u00e7irilip ge\u00e7irilmeyece\u011fini veya etraf\u0131na sar\u0131laca\u011f\u0131n\u0131 genellikle belirler.<\/p>\n<p>Kablonun ba\u011fl\u0131 kalmas\u0131 en az kesintiye neden olan y\u00f6ntemdir; ancak bu, \u00e7er\u00e7eve ve contan\u0131n tam d\u00fczenlemesinin, mevcut bo\u015flukta bozulmam\u0131\u015f kablo g\u00fczerg\u00e2h\u0131na uyaca\u011f\u0131 \u015fekilde belgelenmi\u015f oldu\u011fu durumlarda ge\u00e7erlidir. Bu fiziksel bir kontrold\u00fcr: yar\u0131k veya kelep\u00e7e tipi conta bile\u015fenleri, kablonun \u00fczerine yanlamas\u0131na yerle\u015ftirilmeli ve kablonun etraf\u0131nda kapat\u0131lmal\u0131d\u0131r; ayr\u0131ca \u00e7er\u00e7eve, kablonun zaten bir k\u0131sm\u0131n\u0131 kaplad\u0131\u011f\u0131 duvar a\u00e7\u0131kl\u0131\u011f\u0131na monte edilmelidir. Bu d\u00fczenlemeyi uygulamaya koymadan \u00f6nce belgelendirin; \u201ckablonun etraf\u0131nda \u00e7al\u0131\u015fmak m\u00fcmk\u00fcn olmal\u0131\u201d ifadesi, mevcut bo\u015flukta par\u00e7alar\u0131n birbirine nas\u0131l oturdu\u011funu g\u00f6steren bir \u00e7izimle ayn\u0131 anlama gelmez.<\/p>\n<p>Belirtilen montaj par\u00e7as\u0131, ba\u011fl\u0131 kablo hatt\u0131n\u0131n etraf\u0131na tak\u0131lamad\u0131\u011f\u0131nda, tek bir se\u00e7ene\u011fe otomatik olarak y\u00f6nelmek yerine iki alternatifi kar\u015f\u0131la\u015ft\u0131r\u0131n. Planl\u0131 ba\u011flant\u0131 kesme ve yeniden besleme, bu iki se\u00e7enekten daha basit olan\u0131d\u0131r ve konekt\u00f6r \u00f6nerilen montaj par\u00e7as\u0131ndan ge\u00e7iyorsa, \u015fantiyede ba\u011flant\u0131 kesilmesine izin veriliyorsa ve orijinal duvar detay\u0131 h\u00e2l\u00e2 uygunsa, genellikle ilk tercih edilen se\u00e7enektir. Kablonun hi\u00e7 devre d\u0131\u015f\u0131 b\u0131rak\u0131lamad\u0131\u011f\u0131 durumlarda \u2014 s\u00fcrekli \u00e7al\u0131\u015fan bir proseste bulunan bir cihaz veya tesisin \u00e7al\u0131\u015fma s\u0131ras\u0131nda ihtiya\u00e7 duydu\u011fu bir izleme devresi gibi \u2014 kabloyu farkl\u0131 bir ge\u00e7i\u015f noktas\u0131na y\u00f6nlendirmek veya belgelenmi\u015f farkl\u0131 bir montaj se\u00e7mek tercih edilen yol olur. Kesintiye u\u011frat\u0131lamayan bir kablo, yenileme \u00e7al\u0131\u015fmas\u0131n\u0131n geometrisini de\u011fi\u015ftirir; bu nedenle, ba\u011flant\u0131 noktas\u0131 belirlenmeden \u00f6nce kablonun durumunu erkenden tespit edin.<\/p>\n<h2 id=\"specifysealsandsupportsfortheinstalledcables\">Kurulan kablolar i\u00e7in contalar\u0131 ve destekleri belirleyin<\/h2>\n<p>A\u00e7\u0131kl\u0131ktan birden fazla kablo ge\u00e7ti\u011fi durumlarda, ba\u011flant\u0131 noktas\u0131 \u00e7iziminde her bir kablo kendi konumunda ve kendi k\u0131l\u0131f \u00e7ap\u0131yla g\u00f6sterilmelidir; zira s\u0131zd\u0131rmazl\u0131k temas\u0131, kablo demetinin tamam\u0131 \u00fczerinden de\u011fil, kablo baz\u0131nda sa\u011flan\u0131r. \u00c7aplar\u0131 tek tek listeleyin, her bir kablonun planlanan konumunu \u00e7izimde i\u015faretleyin ve yedek konumlar\u0131, bunlar\u0131n s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 sa\u011flamak i\u00e7in kullan\u0131lacak olan belgelenmi\u015f kapatma detaylar\u0131yla belirtin. \u00c7izimde belirtilmeyen bir yedek konum, duvarda da genellikle dikkate al\u0131nmaz.<\/p>\n<p>Kablo demetleri nadiren duvara d\u00fcz bir \u015fekilde girer. Demet bir tarafa do\u011fru \u00e7ekiliyorsa \u2014 \u00f6rne\u011fin, duvar\u0131n hemen d\u0131\u015f\u0131nda y\u00f6n de\u011fi\u015ftiren bir kablo kanal\u0131 ya da hizmet taraf\u0131nda uzun bir desteksiz ini\u015f \u2014 destekler bu y\u00fck\u00fc \u00f6nceden \u00fcstlenmedik\u00e7e yanal y\u00fck contaya biner. \u00c7izimde duvar\u0131n her iki taraf\u0131ndaki destekleri, destek ile ba\u011flant\u0131 noktas\u0131 aras\u0131ndaki kullan\u0131labilir gev\u015feklik ile birlikte g\u00f6sterin; b\u00f6ylece kurulan kablo, conta taraf\u0131ndan yerinde tutulmak yerine contan\u0131n i\u00e7ine tam olarak oturur. Termal d\u00f6ng\u00fcler, bak\u0131m s\u0131ras\u0131nda \u00e7ekme i\u015flemleri veya titre\u015fimden kaynaklanan hareketler destekler taraf\u0131ndan emilmelidir.<\/p>\n<p>Kablolar\u0131 tek bir s\u0131zd\u0131rmazl\u0131k noktas\u0131ndan grupland\u0131rmak, bazen bir a\u00e7\u0131kl\u0131\u011fa daha fazlas\u0131n\u0131 s\u0131\u011fd\u0131rman\u0131n bir yolu olarak \u00f6nerilir; ancak bunu, sunulan d\u00fczenlemede a\u00e7\u0131k\u00e7a belirtilmesi gereken bir husus olarak de\u011ferlendirin ve k\u0131l\u0131f \u00e7aplar\u0131n\u0131n tam kombinasyonunu g\u00f6sterin. Biti\u015fik k\u0131l\u0131flar aras\u0131ndaki bo\u015fluklar, do\u011fa\u00e7lama bir grupland\u0131rmay\u0131 ge\u00e7ersiz k\u0131lan unsurdur ve yaln\u0131zca belgelenmi\u015f d\u00fczenleme, belirli bir grupland\u0131rman\u0131n s\u0131zd\u0131rmaz oldu\u011funu kan\u0131tlar.<\/p>\n<p>Kimyasal maruziyet de ayn\u0131 anda belirtilir ve bu, tek bir conta yerine iki conta i\u00e7in ge\u00e7erlidir. Oda fumigasyona uygunsa veya sahada kullan\u0131lan temizlik maddeleri duvara ula\u015f\u0131yorsa, ba\u011flant\u0131 noktas\u0131n\u0131n kablo contalar\u0131n\u0131 ve ba\u011flant\u0131 noktas\u0131 ile duvar aras\u0131ndaki aray\u00fczdeki contay\u0131, projenin kimyasallar\u0131, konsantrasyonlar\u0131 ve temas ko\u015fullar\u0131 a\u00e7\u0131s\u0131ndan kontrol edin; her biri i\u00e7in maddi kan\u0131t sunun. Bunlar genellikle farkl\u0131 konumlarda bulunan farkl\u0131 malzemelerdir ve kablo contas\u0131 i\u00e7in uyumluluk verileri, duvardaki conta veya s\u0131zd\u0131rmazl\u0131k maddesi hakk\u0131nda hi\u00e7bir bilgi vermez. \u0130svi\u00e7re BSL-3 tavsiyesi, fumigasyona uygun s\u0131n\u0131rlar i\u00e7in tam da bu ba\u011flamda conta malzemesinin kimyasal direncini g\u00fcndeme getirir; ancak ba\u011flay\u0131c\u0131 olmayan ulusal bir k\u0131lavuz olarak belirli bir \u00fcr\u00fcn i\u00e7in kabul edilebilirlik e\u015fi\u011fi belirlemez. Pratik ad\u0131m, madde listesini erken belirlemek ve <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/vacu-pass-materials-cleaning-and-fumigation-evidence-to-request\/\">her bir m\u00fch\u00fcr konumu i\u00e7in maddi delil<\/a> liman d\u00fczenlemesi kesinle\u015fmeden \u00f6nce.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"plantheoutagebeforeopeningthebarrier\">Bariyeri a\u00e7madan \u00f6nce kesintiyi planlay\u0131n<\/h2>\n<p>Bir ba\u011flant\u0131 noktas\u0131 kurmak i\u00e7in koruma duvar\u0131n\u0131n a\u00e7\u0131lmas\u0131, \u015fantiyenin y\u00f6netmesi gereken iki e\u015fzamanl\u0131 durumu ortaya \u00e7\u0131kar\u0131r: bu kablolar \u00fczerinden ge\u00e7en hizmetlerin kesintiye u\u011framas\u0131 ve bariyerin kendisinde meydana gelen ge\u00e7ici bir de\u011fi\u015fiklik. Her ikisi de kurulum ayr\u0131nt\u0131lar\u0131 kapsam\u0131nda \u00e7\u00f6z\u00fclmedi\u011finden, i\u015f emri verilmeden \u00f6nce her iki durum \u00fczerinde de mutabakat sa\u011flan\u0131r.<\/p>\n<p>Etkilenen kablo hatlar\u0131n\u0131, \u00e7al\u0131\u015fma s\u0131ras\u0131nda kullan\u0131lacak kablo \u00e7izelgesine g\u00f6re her iki ucundan fiziksel olarak etiketleyin. Kablolar\u0131n ba\u011flant\u0131s\u0131n\u0131n kesilip yeniden ba\u011fland\u0131\u011f\u0131 yerlerde, etiketleme devrelerin do\u011fru u\u00e7lara yeniden ba\u011flanmas\u0131n\u0131 sa\u011flar; kablolar\u0131n ba\u011fl\u0131 kald\u0131\u011f\u0131 yerlerde ise hangi k\u0131s\u0131mlara m\u00fcdahale edilmemesi gerekti\u011fini belirtir. Hizmet kesintisi s\u00fcresini, bu devrelerin kullan\u0131c\u0131lar\u0131yla (bu devrelere ba\u011fl\u0131 izleme veya alarm i\u015flevleri dahil) mutab\u0131k kal\u0131n ve kesinti s\u00fcresince s\u0131n\u0131rda \u00e7al\u0131\u015fmalar\u0131 kimin kontrol edece\u011fini belirleyin \u2014 \u00e7al\u0131\u015fmaya ba\u015flamak i\u00e7in kimin izni gereklidir ve \u00e7al\u0131\u015fmay\u0131 sonland\u0131rmak i\u00e7in kimin onay\u0131 gereklidir.<\/p>\n<p>Bariyer a\u00e7\u0131lmadan \u00f6nce yap\u0131lacak dekontaminasyon, tesis risk de\u011ferlendirmesi kapsam\u0131nda al\u0131nan bir karard\u0131r; tesisin varsay\u0131lan ayar\u0131 de\u011fildir. <a href=\"https:\/\/www.cdc.gov\/labs\/media\/pdfs\/2025\/08\/SF__19a_308133-A_BMBL6_00-BOOK-WEB-final-3.pdf\">CDC\/NIH BMBL, alt\u0131nc\u0131 bask\u0131<\/a>, belirli yenileme veya bak\u0131m \u00e7al\u0131\u015fmalar\u0131 da dahil olmak \u00fczere, tan\u0131mlanm\u0131\u015f olaylar\u0131n ard\u0131ndan dekontaminasyon i\u00e7in BSL-3 tesisi h\u00fck\u00fcmlerini i\u00e7erir; bu, tavsiye niteli\u011finde bir ABD k\u0131lavuzudur ve risk de\u011ferlendirmesi, y\u00f6ntem ile malzemeleri belirler; her duruma uygulanacak evrensel bir gaz d\u00f6ng\u00fcs\u00fc bulunmamaktad\u0131r. Program kesinle\u015fmeden \u00f6nce bu konudaki karar\u0131 yaz\u0131l\u0131 olarak biyog\u00fcvenlik biriminden isteyin; zira gerekli alan dekontaminasyonu ve havaland\u0131rma i\u015flemleri, kesinti s\u00fcresini \u00f6nemli \u00f6l\u00e7\u00fcde de\u011fi\u015ftirir.<\/p>\n<h2 id=\"verifytheinstalledsealbeforethelabreturnstoservice\">Laboratuvar yeniden hizmete girmeden \u00f6nce tak\u0131l\u0131 contay\u0131 kontrol edin<\/h2>\n<table>\n<thead>\n<tr>\n<th>Kontrol et<\/th>\n<th>Bundan ne anla\u015f\u0131l\u0131r?<\/th>\n<th>Kay\u0131t kapsam\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>G\u00f6rsel inceleme<\/td>\n<td>Contalarda g\u00f6zle g\u00f6r\u00fcl\u00fcr bo\u015fluklar\u0131 veya k\u00f6t\u00fc oturmay\u0131 tespit eder<\/td>\n<td>Kablo konumlar\u0131 ve ba\u011flant\u0131 noktas\u0131 ile duvar aras\u0131ndaki aray\u00fcz<\/td>\n<\/tr>\n<tr>\n<td>Uygulanabildi\u011fi durumlarda yerel hava ak\u0131\u015f\u0131 kontrol\u00fc<\/td>\n<td>Kav\u015fakta hava ak\u0131\u015f yolunun belirlenmesine yard\u0131mc\u0131 olur<\/td>\n<td>Test yeri ve ko\u015fullar\u0131 (i\u00e7eriye hava ak\u0131\u015f\u0131 gereklili\u011fi dahil)<\/td>\n<\/tr>\n<tr>\n<td>Gerekti\u011finde oda s\u0131zd\u0131rmazl\u0131k testi<\/td>\n<td>Monte edilmi\u015f odan\u0131n s\u0131n\u0131rlar\u0131n\u0131 de\u011ferlendirir<\/td>\n<td>Oda ve test ko\u015fullar\u0131 ile onar\u0131m ve tekrar yap\u0131lan test sonu\u00e7lar\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Montaj sonras\u0131 do\u011frulama, iki farkl\u0131 soruyu ele al\u0131r: ba\u011flant\u0131 noktas\u0131n\u0131n kendisinin do\u011fru \u015fekilde s\u0131zd\u0131rmaz hale getirilip getirilmedi\u011fi ve monte edilen oda s\u0131n\u0131r\u0131n\u0131n i\u015flevini yerine getirip getirmedi\u011fi. Her bir kablo konumunun ve ba\u011flant\u0131 noktas\u0131 ile duvar aras\u0131ndaki aray\u00fcz\u00fcn g\u00f6rsel olarak incelenmesi, g\u00f6zle g\u00f6r\u00fcl\u00fcr bo\u015fluklar\u0131, yanl\u0131\u015f hizalanm\u0131\u015f s\u0131zd\u0131rmazl\u0131k par\u00e7alar\u0131n\u0131 veya eksik s\u0131k\u0131\u015ft\u0131rmay\u0131 tespit eder. Saha test plan\u0131nda \u00f6ng\u00f6r\u00fcld\u00fc\u011f\u00fc durumlarda, odan\u0131n normal bas\u0131n\u00e7 ko\u015fullar\u0131 alt\u0131nda ge\u00e7i\u015f noktas\u0131nda duman kalemi veya e\u015fde\u011feri kullan\u0131larak yap\u0131lan yerel hava ak\u0131\u015f\u0131 kontrol\u00fc, ge\u00e7i\u015f noktas\u0131ndaki hava ak\u0131\u015f\u0131 yolunun tespit edilmesine yard\u0131mc\u0131 olur. <a href=\"https:\/\/www.canada.ca\/en\/public-health\/services\/canadian-biosafety-standards-guidelines\/third-edition.html\">Kanada Biyog\u00fcvenlik Standard\u0131, \u00fc\u00e7\u00fcnc\u00fc bask\u0131<\/a>, standard\u0131n kapsad\u0131\u011f\u0131 muhafaza b\u00f6lgeleri ve muhafaza seviyeleri i\u00e7inde, i\u00e7e do\u011fru hava ak\u0131\u015f\u0131n\u0131n gerekli oldu\u011fu ge\u00e7i\u015f noktalar\u0131nda yap\u0131lan g\u00f6rsel ve duman kalemi kontrollerini a\u00e7\u0131klamaktad\u0131r.<\/p>\n<p>Yerel bir kontrol, bir kusuru tespit eder; ancak s\u0131n\u0131r\u0131n tamam\u0131n\u0131 tan\u0131mlamaz. Projenin gerektirdi\u011fi durumlarda yap\u0131lan oda s\u0131zd\u0131rmazl\u0131k testi, monte edilmi\u015f oday\u0131 de\u011ferlendirir. Kanada Biyog\u00fcvenlik Standard\u0131\u2019ndaki oda bas\u0131n\u00e7 d\u00fc\u015f\u00fc\u015f\u00fc h\u00fckm\u00fc, belirtilen CL3-Ag ve CL4 kapsam\u0131 i\u00e7inde yer al\u0131r; dolay\u0131s\u0131yla b\u00f6yle bir testin bu odaya uygulan\u0131p uygulanmayaca\u011f\u0131, yenileme \u00e7al\u0131\u015fmas\u0131n\u0131n kendisinden ziyade tesisin muhafaza seviyesine ve projenin test plan\u0131na ba\u011fl\u0131d\u0131r. Ger\u00e7ekle\u015ftirilen her i\u015flemin kapsam\u0131n\u0131 ve ko\u015fullar\u0131n\u0131 kaydedin; bir s\u0131z\u0131nt\u0131 tespit edilirse, onar\u0131m ve tekrar kontrol i\u015flemlerinin yan\u0131 s\u0131ra nihai sonucu da kaydedin. Laboratuvar\u0131n tekrar hizmete a\u00e7\u0131lmas\u0131na ili\u015fkin karar, kay\u0131tlarda yer alan kan\u0131tlara dayanarak projenin onaylanm\u0131\u015f prosed\u00fcr\u00fcne ve belirlenen onaylay\u0131c\u0131ya aittir.<\/p>\n<p>Biyog\u00fcvenli\u011fi etkileyebilecek bir de\u011fi\u015fikli\u011fin ard\u0131ndan yap\u0131lan belgelenmi\u015f do\u011frulama, bu kayd\u0131n bir i\u015f formundaki imzadan ziyade ayr\u0131nt\u0131l\u0131 olmas\u0131 gerekti\u011finin nedenidir. Kablo listesini ve as-built \u00e7izimini g\u00fcncelleyerek yenileme i\u015flemini tamamlay\u0131n: kablolar\u0131n kurulum konumlar\u0131ndaki kimlik numaralar\u0131, yedek konumlar\u0131n \u201ckullan\u0131lm\u0131\u015f\u201d olarak i\u015faretlenmesi veya kapatma detay\u0131 uygulanarak m\u00fch\u00fcrlenmesi ve ba\u011flant\u0131 noktas\u0131 ile duvar s\u0131zd\u0131rmazl\u0131k konfig\u00fcrasyonunun as-built hali. Test kayd\u0131n\u0131 bu \u00e7izim revizyonuna ba\u011flay\u0131n. B\u00f6ylece bak\u0131m ekibi, devir teslim s\u0131ras\u0131nda nelerin do\u011fruland\u0131\u011f\u0131n\u0131 ve daha sonra yap\u0131lan kablo de\u011fi\u015fikliklerini ay\u0131rt edebilir ve gelecekte eklenecek bir kablonun s\u0131n\u0131r\u0131n hangi k\u0131sm\u0131n\u0131 etkileyece\u011fini belirleyebilir. <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/vacu-pass-rfq-cable-schedule-wall-detail-and-test-scope\/\">Liman\u0131n kendisi i\u00e7in bir tedarik\u00e7iye ba\u015fvurmadan \u00f6nce<\/a>, elinizde \u00f6l\u00e7\u00fcm verileri bulunmal\u0131d\u0131r \u2014 a\u00e7\u0131k kanal boyutlar\u0131 ve duvar ya da man\u015fon detaylar\u0131, kablo ba\u015f\u0131na k\u0131l\u0131f \u00e7aplar\u0131 ve konekt\u00f6r hatlar\u0131, istenen yedek par\u00e7a konumlar\u0131, kullan\u0131lan dezenfeksiyon ve temizlik maddeleri ile tesisin ger\u00e7ekle\u015ftirmeyi planlad\u0131\u011f\u0131 testlerin kapsam\u0131.<\/p>\n<h2 id=\"frequentlyaskedquestions\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<p><strong>Q:<\/strong> Tek bir b\u00fcy\u00fck boy fi\u015f, t\u00fcm kablolar\u0131n \u00e7\u0131kar\u0131lmas\u0131 gerekti\u011fi anlam\u0131na m\u0131 gelir?<br \/>\n<strong>A:<\/strong> Hay\u0131r, otomatik olarak de\u011fil. Bu kabloyu \u015femada ayr\u0131 olarak i\u015faretleyin ve farkl\u0131 bir g\u00fczerg\u00e2h se\u00e7ildi\u011finde \u00e7er\u00e7evenin di\u011fer kablolar\u0131n etraf\u0131na s\u0131\u011f\u0131p s\u0131\u011fmad\u0131\u011f\u0131n\u0131 kontrol edin. Ortak \u00e7er\u00e7eve birka\u00e7 kabloyu engelliyorsa, bu kablolar\u0131n kesintilerini birlikte planlay\u0131n.<\/p>\n<p><strong>Q:<\/strong> \u00c7ap\u0131n\u0131 hen\u00fcz bilmesem de, ileride eklenecek bir kablo i\u00e7in yer ay\u0131rabilir miyim?<br \/>\n<strong>A:<\/strong> Evet, se\u00e7ilen montajda, kurulu d\u00fczen i\u00e7inde m\u00fch\u00fcrlenebilecek belgelenmi\u015f bir yedek konum varsa. Bunu m\u00fch\u00fcrlenmi\u015f yedek olarak kaydedin ve yeniden a\u00e7madan \u00f6nce yeni kablonun k\u0131l\u0131f\u0131n\u0131n ve konekt\u00f6r\u00fcn\u00fcn uygunlu\u011funu kontrol edin.<\/p>\n<p><strong>Q:<\/strong> Kesinti i\u00e7in rezervasyon yapmadan \u00f6nce fi\u015f bo\u015flu\u011funu kontrol etmeye de\u011fer mi?<br \/>\n<strong>A:<\/strong> Evet. Uygun bir fi\u015f veya fi\u015fin \u00f6l\u00e7\u00fclm\u00fc\u015f d\u0131\u015f hatlar\u0131n\u0131 kullanarak, fi\u015fin boyutundan daha k\u00fc\u00e7\u00fck bir a\u00e7\u0131kl\u0131ktan ge\u00e7irilmesini gerektiren bir g\u00fczerg\u00e2h\u0131 eleyin. Bu kontrol, uyum sorununu \u00f6nceden \u00e7\u00f6zebilir; ancak duvar ba\u011flant\u0131s\u0131n\u0131n kurulum s\u0131ras\u0131nda yine de do\u011frulanmas\u0131 gerekir.<\/p>\n<p><strong>Q:<\/strong> Ya ba\u011flant\u0131 noktas\u0131n\u0131 farkl\u0131 m\u00fcteahhitler kurup duvar\u0131 onarsa ne olur?<br \/>\n<strong>A:<\/strong> \u00c7al\u0131\u015fmaya ba\u015flamadan \u00f6nce monte edilmi\u015f ba\u011flant\u0131 noktas\u0131-duvar contas\u0131n\u0131 kimin kontrol edece\u011fini belirleyin. Her iki y\u00fckleniciden de ayn\u0131 \u00e7izim revizyonunu kullanmalar\u0131n\u0131 ve kablo contalar\u0131 ile duvar ba\u011flant\u0131s\u0131n\u0131 ayn\u0131 \u015fantiye test kayd\u0131na eklemelerini isteyin; b\u00f6ylece hi\u00e7bir aray\u00fcz, iki i\u015f kapsam\u0131 aras\u0131nda kalmaz.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vacu-Pass yenileme \u00e7al\u0131\u015fmas\u0131 s\u0131ras\u0131nda mevcut laboratuvar kablolar\u0131n\u0131n ne zaman ba\u011fl\u0131 kalabilece\u011fini ve laboratuvar\u0131n yeniden hizmete girmeden \u00f6nce duvarda nelerin kontrol edilmesi gerekti\u011fini \u00f6\u011frenin.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"n8n_meta_description":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-7971","post","type-post","status-publish","format-standard","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7971","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/comments?post=7971"}],"version-history":[{"count":1,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7971\/revisions"}],"predecessor-version":[{"id":7972,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7971\/revisions\/7972"}],"wp:attachment":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/media?parent=7971"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/categories?post=7971"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/tags?post=7971"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}