{"id":7798,"date":"2026-10-05T03:12:37","date_gmt":"2026-10-04T19:12:37","guid":{"rendered":"https:\/\/qualia-bio.com\/blog\/fixed-vhp-generator-urs-inputs-engineering-teams-must-define\/"},"modified":"2026-10-05T03:12:38","modified_gmt":"2026-10-04T19:12:38","slug":"fixed-vhp-generator-urs-inputs-engineering-teams-must-define","status":"publish","type":"post","link":"https:\/\/qualia-bio.com\/tr\/blog\/fixed-vhp-generator-urs-inputs-engineering-teams-must-define\/","title":{"rendered":"Sabit VHP Jenerat\u00f6r\u00fc URS: M\u00fchendislik Ekiplerinin Tan\u0131mlamas\u0131 Gereken Giri\u015fler"},"content":{"rendered":"<p>Birden fazla odaya veya b\u00f6lmeye hizmet veren sabit bir VHP jenerat\u00f6r\u00fc, yaln\u0131zca proje kapsam\u0131nda \u015fartname haz\u0131rlanmadan \u00f6nce tan\u0131mlanan g\u00f6revi yerine getirir. Ekipman se\u00e7ilip kurulduktan sonra, sa\u011flad\u0131\u011f\u0131 ar\u0131tma d\u00f6ng\u00fcs\u00fc, odan\u0131n veya s\u00fcrecin ileride ihtiya\u00e7 duyabilece\u011fi \u015fartlara de\u011fil, URS\u2019de belirtilenlere g\u00f6re sabitlenir. Bu belgeyi haz\u0131rlayan m\u00fchendislik ekipleri, fiilen herhangi bir teklifin uymas\u0131 gereken s\u0131n\u0131rlar\u0131 belirlemektedir.<\/p>\n<h2 id=\"startwiththeroomsloadsandintendeddecontaminationduty\">\u00d6ncelikle Odalar, Y\u00fckler ve Planlanan Dekontaminasyon G\u00f6revinden Ba\u015flay\u0131n<\/h2>\n<table>\n<thead>\n<tr>\n<th>URS giri\u015fi<\/th>\n<th>Projenin belirlemesi gerekenler<\/th>\n<th>Karar s\u0131n\u0131r\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0130\u015flem g\u00f6rm\u00fc\u015f muhafaza<\/td>\n<td>G\u00f6rev kapsam\u0131na dahil olan her oda veya di\u011fer kapal\u0131 alan<\/td>\n<td>Teklifi, hedeflenen tedavi s\u0131n\u0131r\u0131na ba\u011fl\u0131 tutar<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma durumu<\/td>\n<td>\u0130\u015flem g\u00f6rm\u00fc\u015f her bir muhafazan\u0131n \u00e7al\u0131\u015fma durumu<\/td>\n<td>Belirtilen g\u00f6revi, yerine getirilece\u011fi ko\u015fullara ba\u011fl\u0131 tutar<\/td>\n<\/tr>\n<tr>\n<td>Temsili y\u00fck<\/td>\n<td>\u00d6ng\u00f6r\u00fclen \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 temsil eden y\u00fck<\/td>\n<td>Sat\u0131c\u0131ya ayn\u0131 y\u00fck esas\u0131n\u0131 sunar<\/td>\n<\/tr>\n<tr>\n<td>S\u00fcrecin amac\u0131<\/td>\n<td>Hedeflenen dekontaminasyon amac\u0131<\/td>\n<td>\u00d6nerilen g\u00f6revin proje amac\u0131na uygun olmas\u0131n\u0131 sa\u011flar<\/td>\n<\/tr>\n<tr>\n<td>Havaland\u0131rma ve serbest b\u0131rakma<\/td>\n<td>Havaland\u0131rma ve tahliye i\u00e7in planlanan g\u00fczerg\u00e2h<\/td>\n<td>Tedaviden taburcu edilmeye kadar belirlenen s\u00fcreci tamamlar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Sabit bir VHP jenerat\u00f6r\u00fc, genel bir alan\u0131 dekontamine etmez. Bu cihaz, tan\u0131mlanm\u0131\u015f bir kapal\u0131 alan\u0131, tan\u0131mlanm\u0131\u015f bir \u00e7al\u0131\u015fma durumunda, tan\u0131mlanm\u0131\u015f bir y\u00fck ta\u015f\u0131rken, tan\u0131mlanm\u0131\u015f bir ama\u00e7 do\u011frultusunda ve havaland\u0131rma ve tahliye yoluyla tan\u0131mlanm\u0131\u015f bir \u00e7\u0131k\u0131\u015f rotas\u0131 \u00fczerinden i\u015fler. Bu unsurlar\u0131n her biri, bir tedarik\u00e7inin inand\u0131r\u0131c\u0131 bir \u015fekilde sunabilece\u011fi teklifi etkiler; bunlardan birini di\u011ferlerini dikkate almadan de\u011fi\u015ftirmek, daha sonra do\u011frulanamayacak bir teknik \u015fartnameye yol a\u00e7ar.<\/p>\n<p>\u0130\u015flem g\u00f6ren b\u00f6lmenin \u00f6nemi, tek bir jenerat\u00f6r\u00fcn tek bir odaya ya da birbirine ba\u011fl\u0131 birka\u00e7 alana hizmet verebilmesi ve projenin bir izolasyon odas\u0131, bir aktar\u0131m alan\u0131 veya birbirine ba\u011fl\u0131 bir oda grubunu kapsamas\u0131na ba\u011fl\u0131 olarak g\u00f6rev tan\u0131m\u0131n\u0131n de\u011fi\u015fmesinden kaynaklanmaktad\u0131r. Kurulumu genel terimlerle a\u00e7\u0131klamak yerine her bir b\u00f6lmeye ayr\u0131 ayr\u0131 isim vermek, sunulan g\u00f6rev tan\u0131m\u0131n\u0131n fiilen onaylanacak olanla uyumlu kalmas\u0131n\u0131 sa\u011flar.<\/p>\n<p>\u00c7al\u0131\u015fma durumu, kapal\u0131 alan\u0131n kendisinden ayr\u0131 bir de\u011fi\u015fkendir. \u00c7al\u0131\u015fma d\u0131\u015f\u0131 durumda dekontamine edilen ayn\u0131 oda, proses ekipmanlar\u0131n\u0131n kurulu oldu\u011fu, kap\u0131lar\u0131n biti\u015fik alanlara a\u00e7\u0131k oldu\u011fu veya hava i\u015fleme sisteminin belirli bir konfig\u00fcrasyonda \u00e7al\u0131\u015ft\u0131\u011f\u0131 ayn\u0131 odaya k\u0131yasla farkl\u0131 bir y\u00fck ve farkl\u0131 bir s\u0131zma zorlu\u011fu ta\u015f\u0131r. URS\u2019de i\u015fleme tabi tutulan her bir kapal\u0131 alan i\u00e7in \u00e7al\u0131\u015fma durumu belirtilmedi\u011fi durumlarda, iki tedarik\u00e7i ayn\u0131 gereksinimi kar\u015f\u0131l\u0131yor gibi g\u00f6r\u00fcn\u00fcrken i\u015flevsel olarak farkl\u0131 d\u00f6ng\u00fcler \u00f6nerebilir.<\/p>\n<p>Temsili y\u00fck, \u00e7al\u0131\u015fma durumundan do\u011frudan kaynaklan\u0131r. Bo\u015f bir kabin \u00fczerinde do\u011frulanm\u0131\u015f bir d\u00f6ng\u00fc, kabinin \u00fcretim s\u0131ras\u0131nda fiilen ta\u015f\u0131yaca\u011f\u0131 y\u00fcke kar\u015f\u0131 performans\u0131 kan\u0131tlamaz. \u0130hale tekliflerinin sunulmas\u0131ndan sonra proje kapsam\u0131nda temsili y\u00fckte bir de\u011fi\u015fiklik yap\u0131l\u0131rsa, tedarik\u00e7inin tasar\u0131m esas\u0131 da buna g\u00f6re de\u011fi\u015fir ve daha \u00f6nceki esasa g\u00f6re yap\u0131lan kar\u015f\u0131la\u015ft\u0131rmalar art\u0131k ge\u00e7erlili\u011fini yitirir.<\/p>\n<p>S\u00fcrecin amac\u0131, ba\u011flamdan \u00e7\u0131kar\u0131lmak yerine a\u00e7\u0131k\u00e7a belirtilmelidir. Personelin tekrar giri\u015fini desteklemek amac\u0131yla yap\u0131lan bir dekontaminasyon g\u00f6revi, malzeme transferini veya kampanyalar aras\u0131ndaki oda haz\u0131rl\u0131\u011f\u0131n\u0131 desteklemek amac\u0131yla yap\u0131lan bir g\u00f6revden farkl\u0131 beklentiler i\u00e7erir ve belirtilen ama\u00e7, projenin daha sonra kabul kriterlerini nas\u0131l tan\u0131mlayaca\u011f\u0131yla uyumlu olmal\u0131d\u0131r.<\/p>\n<p>Havaland\u0131rma ve serbest b\u0131rakma, g\u00f6rev tan\u0131m\u0131n\u0131 tamamlar. Art\u0131k hidrojen peroksitin tahliye edilmesi i\u00e7in tan\u0131mlanm\u0131\u015f bir yolun bulunmad\u0131\u011f\u0131 ve alan\u0131n serbest b\u0131rak\u0131ld\u0131\u011f\u0131n\u0131 beyan etmek i\u00e7in tan\u0131mlanm\u0131\u015f bir dayana\u011f\u0131n bulunmad\u0131\u011f\u0131 bir ar\u0131tma d\u00f6ng\u00fcs\u00fc, g\u00f6revin ikinci yar\u0131s\u0131n\u0131 belirsiz b\u0131rak\u0131r. Serbest b\u0131rakma yolunun mevcut HVAC sisteminden, \u00f6zel havaland\u0131rma ekipman\u0131ndan veya farkl\u0131 bir egzoz yolundan ge\u00e7mesi durumunda, jenerat\u00f6r\u00fcn gerekli kapasitesi ve kontrol s\u0131ras\u0131 buna g\u00f6re de\u011fi\u015fir. Proje, tesisat ve da\u011f\u0131t\u0131m aray\u00fczlerine ge\u00e7meden \u00f6nce, ar\u0131t\u0131lan her bir kapal\u0131 alan i\u00e7in bu be\u015f unsurdan her biri belirlenmelidir; zira a\u015fa\u011f\u0131 ak\u0131\u015ftaki her aray\u00fcz karar\u0131, \u00f6ncelikle g\u00f6revin kesinle\u015ftirilmesine ba\u011fl\u0131d\u0131r.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"defineutilityanddistributioninterfaceswithouthidingscopegaps\">Kapsam Bo\u015fluklar\u0131n\u0131 Gizlemeden Yard\u0131mc\u0131 Program ve Da\u011f\u0131t\u0131m Aray\u00fczlerini Tan\u0131mlama<\/h2>\n<p>G\u00f6rev belirlendikten sonra, URS\u2019de jenerat\u00f6r\u00fcn tesise nas\u0131l ba\u011flanaca\u011f\u0131 a\u00e7\u0131klanmal\u0131d\u0131r; i\u015fte bu noktada kapsam s\u0131n\u0131rlar\u0131 genellikle a\u00e7\u0131k\u00e7a belirtilmek yerine \u00f6rt\u00fck olarak b\u0131rak\u0131l\u0131r. Sabit bir VHP jenerat\u00f6r\u00fc i\u00e7in g\u00fc\u00e7, hidrojen peroksit kayna\u011f\u0131 ve bunun i\u015flenmesi i\u00e7in tan\u0131mlanm\u0131\u015f bir y\u00f6ntem, buhar\u0131n i\u015flenen alana da\u011f\u0131t\u0131lmas\u0131 i\u00e7in bir yol, bir egzoz yolu ve sistemin \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131 ve bak\u0131m\u0131 i\u00e7in gerekli damperler, sens\u00f6rler ve servis eri\u015fimi gereklidir. Bunlar\u0131n hi\u00e7birinin varsay\u0131lan olarak ekipman sat\u0131c\u0131s\u0131n\u0131n kapsam\u0131na girdi\u011fini veya girmedi\u011fini varsaymamak gerekir.<\/p>\n<p>Jenerat\u00f6r\u00fc odaya ba\u011flayan da\u011f\u0131t\u0131m borular\u0131 veya kanal sistemi ile da\u011f\u0131t\u0131m ya da egzoz amac\u0131yla mevcut HVAC altyap\u0131s\u0131n\u0131n ortak kullan\u0131m\u0131, do\u011fal bir aray\u00fcz s\u0131n\u0131r\u0131nda yer al\u0131r. Projenin buhar\u0131 mevcut kanal sistemi \u00fczerinden y\u00f6nlendirmeyi ama\u00e7lad\u0131\u011f\u0131 durumlarda, URS bu niyeti tedarik\u00e7inin kendi ba\u015f\u0131na \u00e7\u0131karsamas\u0131na b\u0131rakmak yerine do\u011frudan belirtmelidir; zira hem jenerat\u00f6r\u00fcn da\u011f\u0131t\u0131m tasar\u0131m\u0131 hem de tesisin HVAC tasar\u0131m\u0131, her bir taraf\u0131n bu aray\u00fcz\u00fcn hangi taraf\u0131na sahip oldu\u011funa ba\u011fl\u0131d\u0131r. Ayn\u0131 durum egzoz i\u00e7in de ge\u00e7erlidir: Jenerat\u00f6r\u00fcn egzozunun \u00f6zel bir yola y\u00f6nlendirilmesi veya mevcut bir egzoz sistemini payla\u015fmas\u0131, tesis ekibinin neyi sa\u011flamas\u0131 gerekti\u011fini ve ekipman tedarik\u00e7isinin s\u0131n\u0131r ko\u015fulu olarak neyi kabul etmesi gerekti\u011fini de\u011fi\u015ftirir.<\/p>\n<p>Damperler ve sens\u00f6rler bu ayn\u0131 aray\u00fcz hatt\u0131nda yer al\u0131r. Damper kontrol\u00fc, projenin sorumluluk yap\u0131s\u0131na ba\u011fl\u0131 olarak jenerat\u00f6r\u00fcn kontrol sistemine, bina y\u00f6netim sistemine ait olabilir veya bu iki sistem aras\u0131nda payla\u015ft\u0131r\u0131labilir; URS, damperlerin kime ait olaca\u011f\u0131 konusunu devreye alma a\u015famas\u0131nda \u00e7\u00f6z\u00fclmeye b\u0131rakmak yerine, hangi durumun ge\u00e7erli oldu\u011funu belirtmelidir. Jenerat\u00f6r\u00fcn kendisini izleyen sens\u00f6rlerden farkl\u0131 olarak, i\u015flenen kapal\u0131 alan i\u00e7indeki d\u00f6ng\u00fc parametrelerini do\u011frulamaya y\u00f6nelik sens\u00f6rlerin yerle\u015ftirilmesi, ekipman taraf\u0131 ile tesis taraf\u0131 enstr\u00fcmantasyonu aras\u0131ndaki ayr\u0131m\u0131n izlenebilir olmas\u0131 i\u00e7in konum ve i\u015flevlerine g\u00f6re tan\u0131mlanmal\u0131d\u0131r.<\/p>\n<p>Hizmet eri\u015fimi, bir kontrol aray\u00fcz\u00fc oldu\u011fu kadar fiziksel bir aray\u00fczd\u00fcr de. Jenerat\u00f6r\u00fcn, hidrojen peroksit beslemesinin veya da\u011f\u0131t\u0131m bile\u015fenlerinin bak\u0131m amac\u0131yla eri\u015fime ihtiya\u00e7 duydu\u011fu durumlarda, URS\u2019de tesisin sa\u011flayaca\u011f\u0131 eri\u015fim ko\u015fullar\u0131 belirtilmelidir; zira hem ekipman yerle\u015fimi hem de tesis d\u00fczeni bu ko\u015fullara ba\u011fl\u0131d\u0131r. Bu aray\u00fczlerden herhangi birinin belirtilmemesi, kapsam sorununu ortadan kald\u0131rmaz; aksine, bu sorunu projenin ilerleyen bir a\u015famas\u0131na erteler ve bu a\u015famada sorunu \u00e7\u00f6zmenin maliyeti, onu tan\u0131mlaman\u0131n maliyetinden daha y\u00fcksek olur.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"specifycontrolstatesinterlocksalarmsanddatarequirements\">Kontrol Durumlar\u0131n\u0131, Kilitlemeleri, Alarmlar\u0131 ve Veri Gereksinimlerini Belirtin<\/h2>\n<p>Kontrol gereklilikleri, sistemin \u00fcretebilece\u011fi her sinyale tek tip bir \u015fekilde uygulanmak yerine, projenin GMP a\u00e7\u0131s\u0131ndan ger\u00e7ekte neyin \u00f6nemli oldu\u011funa g\u00f6re belirlenmelidir. Sabit bir VHP \u00fcretecinin kontrol sistemi, izin sinyalleri, kilitleme sinyalleri, alarmlar, kullan\u0131c\u0131 eri\u015fim k\u0131s\u0131tlamalar\u0131, saklanan veriler ve bina y\u00f6netim sistemine g\u00f6nderilen sinyaller \u00fcretebilir; bu kategorilerin her biri, projenin neyi kan\u0131tlamas\u0131 gerekti\u011fine ba\u011fl\u0131 olarak farkl\u0131 bir \u00f6neme sahiptir.<\/p>\n<p>\u0130zin ko\u015fullar\u0131 ve kilitleme mekanizmalar\u0131, bir d\u00f6ng\u00fcn\u00fcn ba\u015flay\u0131p ba\u015flayamayaca\u011f\u0131n\u0131 veya durmas\u0131 gerekip gerekmedi\u011fini belirler; projede, i\u015flemin ba\u015flamas\u0131 i\u00e7in hangi ko\u015fullar\u0131n ge\u00e7erli olmas\u0131 gerekti\u011fi ve i\u015flem s\u0131ras\u0131nda hangi ko\u015fullar\u0131n d\u00f6ng\u00fcn\u00fcn durdurulmas\u0131n\u0131 gerektirdi\u011fi a\u00e7\u0131k\u00e7a belirtilmelidir. Bir kilitleme mekanizmas\u0131n\u0131n jenerat\u00f6r\u00fcn \u00e7al\u0131\u015fmas\u0131n\u0131 bir kap\u0131 konumuna, bir damper durumuna veya biti\u015fik bir odan\u0131n durumuna ba\u011flad\u0131\u011f\u0131 durumlarda, bu ili\u015fki URS\u2019de tan\u0131mlanm\u0131\u015f bir ko\u015ful olarak belirtilmeli ve kontrol sisteminin varsay\u0131lan davran\u0131\u015f\u0131na b\u0131rak\u0131lmamal\u0131d\u0131r.<\/p>\n<p>Alarmlar konusunda da, bilgilendirme ama\u00e7l\u0131 olanlar ile belirli bir m\u00fcdahale gerektirenler aras\u0131nda benzer bir ayr\u0131m yap\u0131lmas\u0131 gerekir. Jenerat\u00f6r\u00fcn \u00fcretebilece\u011fi her alarm\u0131n sonu\u00e7lar\u0131 ayn\u0131 de\u011fildir; bu nedenle projede, hangi alarmlar\u0131n operat\u00f6r m\u00fcdahalesi gerektirdi\u011fi, hangilerinin belgelenmi\u015f bir sapma kayd\u0131 gerektirdi\u011fi ve hangilerinin yaln\u0131zca bilgilendirme ama\u00e7l\u0131 oldu\u011fu belirtilmelidir.<\/p>\n<p>Kullan\u0131c\u0131 eri\u015fimi ve veri saklama, verilerin a\u015fa\u011f\u0131daki h\u00fck\u00fcmler kapsam\u0131nda parti serbest b\u0131rakma, sapma ara\u015ft\u0131rmas\u0131 veya denetim izi gerekliliklerini destekledi\u011fi durumlarda GMP a\u00e7\u0131s\u0131ndan \u00f6nem kazan\u0131r: <a href=\"https:\/\/health.ec.europa.eu\/system\/files\/2016-11\/annex11_01-2011_en_0.pdf\">Ek 11\u2019deki bilgisayarl\u0131 sistem \u00e7er\u00e7evesi<\/a>, ; bu, kullan\u0131c\u0131 gereksinimlerinin risk temelli do\u011frulanmas\u0131n\u0131 ve denetim izleri, depolanan veriler, yedeklemeler ve eri\u015fim \u00fczerindeki kontrolleri gerektirmektedir. Ek 11\u2019in kapsam\u0131, kontrol sisteminin kaydedebilece\u011fi her tesis olay\u0131na otomatik olarak geni\u015flemek yerine, belgelenmi\u015f riski takip eder; bir veri noktas\u0131 bir GMP karar\u0131n\u0131 desteklemedi\u011finde, bunu destekleyen verilerle ayn\u0131 titizlikle ele almak, g\u00fcvence sa\u011flamadan kontrol y\u00fck\u00fcn\u00fc art\u0131r\u0131r. Proje, hangi sinyallerin, alarmlar\u0131n ve kay\u0131tlar\u0131n GMP a\u00e7\u0131s\u0131ndan \u00f6nemli oldu\u011funu ve hangilerinin olmad\u0131\u011f\u0131n\u0131 belirlemeli ve mevcut her sinyal i\u00e7in tam bir do\u011frulama titizli\u011fi talep etmek yerine, URS\u2019yi buna g\u00f6re haz\u0131rlamal\u0131d\u0131r.<\/p>\n<p>Bina y\u00f6netim sistemi sinyalleri, jenerat\u00f6r\u00fcn kendi kontrol sistemi ile tesisin daha geni\u015f kapsaml\u0131 izleme sistemi aras\u0131ndaki s\u0131n\u0131rda yer al\u0131r. Belirli bir sinyalin BMS i\u00e7in bilgilendirme ama\u00e7l\u0131 m\u0131 oldu\u011fu yoksa GMP ile ilgili bir kayd\u0131n par\u00e7as\u0131 m\u0131 oldu\u011fu a\u00e7\u0131k\u00e7a belirtilmelidir; zira bu durum, s\u00f6z konusu sinyalin daha sonra jenerat\u00f6r\u00fcn temel kontrol i\u015flevleriyle ayn\u0131 nitelik kan\u0131t\u0131n\u0131 gerektirip gerektirmeyece\u011fini belirler.<\/p>\n<h2 id=\"connecteachursrequirementtofatsatiqandoqevidence\">Her bir URS gereklili\u011fini FAT, SAT, IQ ve OQ kan\u0131tlar\u0131yla ili\u015fkilendirin<\/h2>\n<table>\n<thead>\n<tr>\n<th>Delil a\u015famas\u0131<\/th>\n<th>\u0130lgili her bir URS gereklili\u011fi i\u00e7in izlenebilirlik kayd\u0131<\/th>\n<th>Kan\u0131t s\u0131n\u0131r\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tasar\u0131m incelemesi<\/td>\n<td>S\u00f6z konusu gereksinimi ele alan, belgelenmi\u015f tasar\u0131m incelemesini belirleyin<\/td>\n<td>URS ile tasar\u0131m onay s\u00fcreci aras\u0131ndaki ba\u011flant\u0131y\u0131 s\u00fcrd\u00fcr\u00fcn<\/td>\n<\/tr>\n<tr>\n<td>FAT<\/td>\n<td>Gereksinim i\u00e7in planlanan ve gerek\u00e7elendirilmi\u015f tedarik\u00e7i test kan\u0131tlar\u0131n\u0131 belirleyin<\/td>\n<td>Onaylanm\u0131\u015f bir protokol ve \u00f6nceden tan\u0131mlanm\u0131\u015f, projeye \u00f6zg\u00fc bir kabul kriteri kullan\u0131n<\/td>\n<\/tr>\n<tr>\n<td>SAT<\/td>\n<td>\u0130htiya\u00e7 i\u00e7in planlanan saha testi kan\u0131tlar\u0131n\u0131 belirleyin<\/td>\n<td>Onaylanm\u0131\u015f bir protokol ve \u00f6nceden tan\u0131mlanm\u0131\u015f, projeye \u00f6zg\u00fc bir kabul kriteri kullan\u0131n<\/td>\n<\/tr>\n<tr>\n<td>IQ<\/td>\n<td>S\u00f6z konusu gereklilik i\u00e7in planlanan kurulum uygunluk kan\u0131tlar\u0131n\u0131 belirleyin<\/td>\n<td>IQ kan\u0131tlar\u0131n\u0131 OQ kan\u0131tlar\u0131ndan ayr\u0131 tutun<\/td>\n<\/tr>\n<tr>\n<td>OQ<\/td>\n<td>\u0130htiya\u00e7 i\u00e7in planlanan operasyonel yeterlilik kan\u0131tlar\u0131n\u0131 belirleyin<\/td>\n<td>OQ kan\u0131tlar\u0131n\u0131 IQ kan\u0131tlar\u0131ndan ayr\u0131 tutun<\/td>\n<\/tr>\n<tr>\n<td>Sapma kayd\u0131<\/td>\n<td>Planlanan do\u011frulama faaliyetinden kaynaklanan her t\u00fcrl\u00fc sapmay\u0131 belirtin<\/td>\n<td>Onaylanm\u0131\u015f protokol ve \u00f6nceden belirlenmi\u015f kriterlere g\u00f6re sapmay\u0131 belgelendirin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/how-to-write-testable-urs-requirements-for-isolators-bibo-vhp-pass-boxes-and-eds\/\">URS gereklili\u011fi<\/a> Do\u011frulama a\u015famas\u0131na kadar izi s\u00fcr\u00fclemeyen bir h\u00fck\u00fcm, ne kadar a\u00e7\u0131k bir \u015fekilde yaz\u0131lm\u0131\u015f olursa olsun, daha sonra uygulanmas\u0131 zordur. <a href=\"https:\/\/health.ec.europa.eu\/system\/files\/2016-11\/2015-10_annex15_0.pdf\">Ek 15<\/a> Kullan\u0131c\u0131 gereksinimleri \u015fartnamesini tasar\u0131m onay\u0131na ba\u011flar, saha kabul testleriyle desteklenen ve gerek\u00e7elendirilmi\u015f tedarik\u00e7i fabrika kabul testlerine izin verir ve kurulum onay\u0131 kan\u0131tlar\u0131n\u0131 i\u015fletme onay\u0131 kan\u0131tlar\u0131ndan ay\u0131r\u0131r; t\u00fcm bunlar, \u00f6nceden tan\u0131mlanm\u0131\u015f kabul kriterleri ve belgelenmi\u015f sapmalar i\u00e7eren onaylanm\u0131\u015f protokoller \u00e7er\u00e7evesinde ger\u00e7ekle\u015ftirilir. Bu yap\u0131y\u0131 sabit bir VHP jenerat\u00f6r\u00fcne uygulamak, projenin teklif kar\u015f\u0131la\u015ft\u0131rma a\u015famas\u0131na ge\u00e7meden \u00f6nce, \u00f6nceki b\u00f6l\u00fcmlerdeki her bir ilgili gereksinimin bu kan\u0131t zincirinde belirli bir yere sahip olmas\u0131 gerekti\u011fi anlam\u0131na gelir.<\/p>\n<p>Tasar\u0131m incelemesi ilk kontrol noktas\u0131d\u0131r ve herhangi bir fiziksel test yap\u0131lmadan \u00f6nce, belirtilen g\u00f6rev, aray\u00fczler ve kontrol gerekliliklerinin \u00f6nerilen tasar\u0131ma yans\u0131t\u0131ld\u0131\u011f\u0131n\u0131 do\u011frulamal\u0131d\u0131r. FAT a\u015famas\u0131nda ilk kez ortaya \u00e7\u0131kan bir gereklilik, tasar\u0131m incelemesini fiilen atlam\u0131\u015f demektir ve bu a\u015famada tespit edilen herhangi bir eksikli\u011fin giderilmesi, daha erken tespit edilen bir eksikli\u011fe k\u0131yasla daha maliyetlidir.<\/p>\n<p>FAT ve SAT, sorumlulu\u011fu tedarik\u00e7i tesisinde yap\u0131lan do\u011frulama ile kurulum yerinde yap\u0131lan do\u011frulama aras\u0131nda payla\u015ft\u0131r\u0131r. Bir gereksinimin, gerek\u00e7elendirilmi\u015f bir test d\u00fczeni kullan\u0131larak tedarik\u00e7inin tesisinde anlaml\u0131 bir \u015fekilde test edilebildi\u011fi durumlarda, FAT kan\u0131t\u0131 bu gereksinimi kar\u015f\u0131layabilir; gereksinimin ise ger\u00e7ek muhafazaya ba\u011fl\u0131 bir da\u011f\u0131t\u0131m yolu veya tesisin ger\u00e7ek damperine ba\u011fl\u0131 bir kilit sistemi gibi fiilen kurulmu\u015f aray\u00fczlere ba\u011fl\u0131 oldu\u011fu durumlarda, kan\u0131t\u0131 SAT sa\u011flar. Projede, her \u015feyin yaln\u0131zca FAT ile kar\u015f\u0131lanaca\u011f\u0131 varsay\u0131m\u0131 yerine, hangi gereksinimlerin hangi a\u015famaya ait oldu\u011fu a\u00e7\u0131k\u00e7a belirtilmelidir.<\/p>\n<p>Ek 15 kapsam\u0131nda IQ ve OQ, birbirinden ayr\u0131 kan\u0131t t\u00fcrleri olarak kalmaktad\u0131r ve bunlar\u0131n birbirine kar\u0131\u015ft\u0131r\u0131lmas\u0131, ger\u00e7ekte neyin kan\u0131tland\u0131\u011f\u0131na dair belirsizli\u011fe yol a\u00e7ar. Kurulum yeterlili\u011fi, sistemin belirtildi\u011fi \u015fekilde kuruldu\u011funu teyit eder; i\u015fletme yeterlili\u011fi ise sistemin ama\u00e7lanan aral\u0131kta belirtildi\u011fi \u015fekilde \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 teyit eder. URS\u2019de ad\u0131 ge\u00e7en bir kontrol izni veya kilitleme mekanizmas\u0131, hangisi oldu\u011funu belirtmeyen genel bir yeterlilik beyan\u0131na de\u011fil, bu ikisinden birine kadar izlenebilir olmal\u0131d\u0131r.<\/p>\n<p>Bu a\u015famalara g\u00f6re planlanan her do\u011frulama faaliyeti, \u00f6nceden tan\u0131mlanm\u0131\u015f ve projeye \u00f6zg\u00fc bir kabul kriteri i\u00e7eren onaylanm\u0131\u015f bir protokol kapsam\u0131nda y\u00fcr\u00fct\u00fclmeli ve s\u00f6z konusu faaliyetten kaynaklanan her t\u00fcrl\u00fc sapma, ayn\u0131 kriter \u0131\u015f\u0131\u011f\u0131nda belgelenmelidir. Bu izlenebilirlik \u00e7al\u0131\u015fmas\u0131, ayn\u0131 zamanda, \u00f6nceki b\u00f6l\u00fcmlerde tan\u0131mlanan g\u00f6rev, aray\u00fczler ve kontrol gereklilikleri de dahil olmak \u00fczere jenerat\u00f6r tedarik\u00e7isine sa\u011flanan proje bilgilerinin, s\u00f6z konusu tedarik\u00e7inin konfig\u00fcrasyon ve teklif inceleme s\u00fcrecine dahil edildi\u011fi a\u015famad\u0131r; zira tedarik\u00e7i, <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/what-validation-documentation-to-require-from-vhp-manufacturers-before-rfq\/\">hakl\u0131 FAT kan\u0131t\u0131<\/a> ya da projenin bu s\u0131n\u0131rlar\u0131 nas\u0131l belirledi\u011fini \u00f6nceden g\u00f6rmeden, buna uygun bir kontrol tasar\u0131m\u0131.<\/p>\n<h2 id=\"setbidassumptionsandprojectacceptanceownership\">Teklif Varsay\u0131mlar\u0131n\u0131 Belirleme ve Proje Kabul Sorumlulu\u011funu Tan\u0131mlama<\/h2>\n<p>Yukar\u0131daki b\u00f6l\u00fcmler bir zincir olu\u015fturmaktad\u0131r: her bir kapsama alan\u0131 i\u00e7in tan\u0131mlanm\u0131\u015f bir g\u00f6rev, kapsam sahipli\u011fi belirtilen tan\u0131mlanm\u0131\u015f aray\u00fczler, GMP ile fiili ilgisi dikkate al\u0131narak belirlenmi\u015f kontrol gereklilikleri ve her bir gereklili\u011fin bir do\u011frulama a\u015famas\u0131na izlenebilirli\u011fi. Teklif kar\u015f\u0131la\u015ft\u0131rmas\u0131, her tedarik\u00e7inin farkl\u0131 varsay\u0131mlarla bo\u015fluklar\u0131 doldurmak yerine ayn\u0131 zincire yan\u0131t vermesine ba\u011fl\u0131d\u0131r.<\/p>\n<p>URS\u2019nin bir \u00f6\u011feyi tan\u0131mlamad\u0131\u011f\u0131 durumlarda, sabit bir VHP \u00fcreteci \u00f6neren bir sat\u0131c\u0131, \u00f6rne\u011fin <a href=\"https:\/\/qualia-bio.com\/tr\/product\/spacevhp\/vhp-hydrogen-peroxide-generator-type-i\/\">Tip I \u00fcnitesi<\/a> Bu ekipman kategorisi kapsam\u0131nda sunulan teklifler, genellikle projenin ger\u00e7ek durumundan ziyade standart konfig\u00fcrasyonlar\u0131na uygun bir varsay\u0131mla bu bo\u015flu\u011fu doldurur. Bu, sat\u0131c\u0131n\u0131n teklifindeki bir eksiklik de\u011fil; eksik bir gereksinimin sonucudur. Proje ekibi, teklifler aras\u0131nda \u00f6nemli farkl\u0131l\u0131klar bulunan her alan\u0131, en d\u00fc\u015f\u00fck veya en kapsaml\u0131 teklifi otomatik olarak do\u011fru kabul etmek yerine, URS\u2019nin o unsuru a\u00e7\u0131k b\u0131rakt\u0131\u011f\u0131n\u0131n bir i\u015fareti olarak de\u011ferlendirmelidir.<\/p>\n<p>Kabul kriterlerinin sahipli\u011fi, tasar\u0131m incelemesi, FAT, SAT, IQ ve OQ a\u015famalar\u0131nda ge\u00e7erli olan \u00f6nceden tan\u0131mlanm\u0131\u015f kriterler ilkesiyle tutarl\u0131 olarak, proje s\u00fcresince projeye ait olmal\u0131d\u0131r. Bir tedarik\u00e7i, test y\u00f6ntemleri \u00f6nerebilir ve ekipman\u0131n\u0131n belirtilen bir kriteri kar\u015f\u0131lad\u0131\u011f\u0131n\u0131 g\u00f6sterebilir; ancak kriterin kendisi ve buna ili\u015fkin kan\u0131tlar\u0131n kabul edilmesi veya reddedilmesi karar\u0131 projeye aittir. Bu sorumlulu\u011fun net olmad\u0131\u011f\u0131 durumlarda, tedarik\u00e7inin i\u00e7 test kriterleri projenin kabul standard\u0131 ile kar\u0131\u015ft\u0131r\u0131labilir; bu da, daha sonra bir sapman\u0131n gerek\u00e7elendirilmesi gerekti\u011finde projenin konumunu zay\u0131flat\u0131r.<\/p>\n<p>Daha \u00f6nce g\u00fc\u00e7, hidrojen peroksit beslemesi ve elle\u00e7lemesi, da\u011f\u0131t\u0131m, egzoz, damperler, sens\u00f6rler ve servis eri\u015fimi i\u00e7in belirtilen aray\u00fcz sahipli\u011fi, genel bir kapsam beyan\u0131 olarak b\u0131rak\u0131lmak yerine, ihale varsay\u0131mlar\u0131nda her bir muhafaza i\u00e7in ayr\u0131 ayr\u0131 a\u00e7\u0131k\u00e7a teyit edilmelidir. Tedarik\u00e7inin \u201cjenerat\u00f6r\u00fc ve standart aray\u00fczleri\u201d sa\u011flad\u0131\u011f\u0131na dair genel bir ifade, belirli bir odadaki belirli bir damperin veya belirli bir egzoz ba\u011flant\u0131s\u0131n\u0131n hangi tarafa ait oldu\u011funu netle\u015ftirmez.<\/p>\n<p>Projede, belirli bir muhafazan\u0131n \u00e7al\u0131\u015fma durumu, y\u00fck\u00fc veya serbest b\u0131rakma yolunun nas\u0131l de\u011ferlendirilece\u011finin hen\u00fcz netle\u015ftirilmedi\u011fi durumlarda, bu eksiklik, teklif talebinde a\u00e7\u0131k\u00e7a belirtilmelidir; bu konunun, yan\u0131t veren tedarik\u00e7ilerin ba\u011f\u0131ms\u0131z olarak yorumlamas\u0131na b\u0131rak\u0131lmamal\u0131d\u0131r. Zira her tedarik\u00e7inin yorumu, ortaya \u00e7\u0131kan teklifler i\u00e7in birbirinden farkl\u0131 ve kar\u015f\u0131la\u015ft\u0131r\u0131lamaz bir temel olu\u015fturur.<\/p>\n<h2 id=\"frequentlyaskedquestions\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<p><strong>Q:<\/strong> Tedarik\u00e7iler aray\u00fcz kapsam\u0131n\u0131 farkl\u0131 \u015fekilde belirledi\u011finde, m\u00fchendislik ekipleri sabit VHP jenerat\u00f6r tekliflerini nas\u0131l kar\u015f\u0131la\u015ft\u0131rabilir?<br \/>\n<strong>A:<\/strong> Kar\u015f\u0131la\u015ft\u0131rma yapmadan \u00f6nce her teklifi ayn\u0131 aray\u00fcz listesine g\u00f6re standart hale getirin. Elektrik, hidrojen peroksit tedariki ve elle\u00e7lemesi, da\u011f\u0131t\u0131m borular\u0131 veya HVAC ba\u011flant\u0131s\u0131, egzoz, damperler, sens\u00f6rler ve servis eri\u015fimi konular\u0131nda, tedarik\u00e7inin varsay\u0131mlar\u0131n\u0131 kaydedin ve sahipli\u011fi hen\u00fcz belirlenmemi\u015f t\u00fcm kalemleri tespit edin.<\/p>\n<p><strong>Q:<\/strong> Nihai oda y\u00fck\u00fc hen\u00fcz kesinle\u015fmemi\u015fse, URS\u2019de ne yazmal\u0131d\u0131r?<br \/>\n<strong>A:<\/strong> Teklif talebi (RFQ) i\u00e7in kullan\u0131lan temsili y\u00fck\u00fc tan\u0131mlay\u0131n ve bunun, kesinle\u015fmi\u015f nihai bir ko\u015ful de\u011fil, kar\u015f\u0131la\u015ft\u0131rma temeli oldu\u011funu belirtin. B\u00f6ylece ekip, ileride al\u0131nacak hangi y\u00fck kararlar\u0131n\u0131n \u00f6nerilen i\u015flem y\u00fck\u00fcml\u00fcl\u00fc\u011f\u00fcn\u00fcn g\u00f6zden ge\u00e7irilmesini gerektirece\u011fini belirleyebilir.<\/p>\n<p><strong>Q:<\/strong> Proje, hangi kontrol ve veri gerekliliklerinin GMP ile ilgili oldu\u011funa nas\u0131l karar vermelidir?<br \/>\n<strong>A:<\/strong> Her bir kontrol durumunu, alarm\u0131, kilitleme mekanizmas\u0131n\u0131, kullan\u0131c\u0131 eri\u015fim kural\u0131n\u0131, saklanan kayd\u0131 ve BMS sinyalini, s\u00fcre\u00e7teki ger\u00e7ek rol\u00fcne ve belgelenmi\u015f riske g\u00f6re s\u0131n\u0131fland\u0131r\u0131n. Her tesis olay\u0131n\u0131 ayn\u0131 \u015fekilde ele almak yerine, bu s\u0131n\u0131fland\u0131rmay\u0131 kullanarak ge\u00e7erli eri\u015fim, saklama, denetim izi, yedekleme ve do\u011frulama beklentilerini tan\u0131mlay\u0131n.<\/p>\n<p><strong>Q:<\/strong> Ba\u015far\u0131l\u0131 bir FAT kan\u0131t\u0131, saha testi veya uygunluk kan\u0131t\u0131n\u0131n yerini alabilir mi?<br \/>\n<strong>A:<\/strong> Bu, genel bir kural de\u011fildir. Proje, ilgili gereklilikler i\u00e7in tedarik\u00e7iye ait ge\u00e7erli FAT kan\u0131tlar\u0131n\u0131 kullanabilir; ancak yine de gerekli SAT, IQ ve OQ kan\u0131tlar\u0131n\u0131 ayr\u0131 ayr\u0131 belirlemeli ve ilgili a\u015famada onaylanm\u0131\u015f protokolleri ve \u00f6nceden tan\u0131mlanm\u0131\u015f projeye \u00f6zg\u00fc kabul kriterlerini uygulamal\u0131d\u0131r.<\/p>\n<p><strong>Q:<\/strong> Sabit bir VHP jenerat\u00f6r\u00fcn\u00fcn URS gerekliliklerini neyin test edilebilir k\u0131ld\u0131\u011f\u0131 nedir?<br \/>\n<strong>A:<\/strong> Test edilebilir bir gereksinim, istenen ko\u015fulu planlanm\u0131\u015f bir kan\u0131t a\u015famas\u0131na ve projenin sorumlulu\u011funda olan \u00f6nceden tan\u0131mlanm\u0131\u015f bir kabul kriterine ba\u011flar. Ayr\u0131ca, sapmalar\u0131n nas\u0131l belgelenece\u011fini de belirtmelidir; b\u00f6ylece nihai kan\u0131t\u0131n orijinal gereksinime kadar izlenebilirli\u011fi sa\u011flan\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>Teklif Talebi (RFQ) \u00f6ncesinde odalar\u0131, y\u00fckleri, tesisatlar\u0131, aray\u00fczleri, kontrol sistemlerini ve kan\u0131tlar\u0131 tan\u0131mlay\u0131n; b\u00f6ylece tedarik\u00e7ilerin teklifleri, izlenebilir ve sabit bir VHP y\u00fck\u00fcml\u00fcl\u00fc\u011f\u00fc temelinde kar\u015f\u0131la\u015ft\u0131r\u0131labilir.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"n8n_meta_description":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-7798","post","type-post","status-publish","format-standard","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7798","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/comments?post=7798"}],"version-history":[{"count":1,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7798\/revisions"}],"predecessor-version":[{"id":7799,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7798\/revisions\/7799"}],"wp:attachment":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/media?parent=7798"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/categories?post=7798"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/tags?post=7798"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}