{"id":7774,"date":"2026-09-29T03:12:25","date_gmt":"2026-09-28T19:12:25","guid":{"rendered":"https:\/\/qualia-bio.com\/blog\/bsl-vacu-pass-wall-interface-who-owns-sleeve-seal-and-conduit\/"},"modified":"2026-09-29T03:12:26","modified_gmt":"2026-09-28T19:12:26","slug":"bsl-vacu-pass-wall-interface-who-owns-sleeve-seal-and-conduit","status":"publish","type":"post","link":"https:\/\/qualia-bio.com\/tr\/blog\/bsl-vacu-pass-wall-interface-who-owns-sleeve-seal-and-conduit\/","title":{"rendered":"BSL Vacu-Pass Duvar Aray\u00fcz\u00fc: Man\u015fon, Conta ve Kabloluk Kime Aittir?"},"content":{"rendered":"<p>Bir kablo veya kordon ge\u00e7i\u015fi i\u00e7in duvar deli\u011fi, birbirlerine nadiren at\u0131fta bulunan iki belgenin kesi\u015fti\u011fi noktada yer al\u0131r: duvar yap\u0131m dosyas\u0131 ve ekipman konfig\u00fcrasyonu. Bir <a href=\"https:\/\/qualia-bio.com\/tr\/product\/lockseries\/vacu-pass-cord-and-cable-port\/\">Vacu-Pass ba\u011flant\u0131 noktas\u0131<\/a> Bir BSL-3 bariyeri i\u00e7in belirtilmi\u015f olsa bile, a\u00e7\u0131kl\u0131\u011f\u0131 kimin a\u00e7aca\u011f\u0131na, man\u015fonu kimin temin edip takaca\u011f\u0131na, kablo kanal\u0131n\u0131 kimin sonland\u0131raca\u011f\u0131na ve monte edilen sonucun sipari\u015f edilene uygun olup olmad\u0131\u011f\u0131n\u0131 kimin kontrol edece\u011fine yine de birinin karar vermesi gerekir. Bunlar\u0131n hi\u00e7biri, \u00e7izimde \u00fcr\u00fcn\u00fcn ad\u0131n\u0131n belirtilmesiyle halledilemez.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"wherethecontainmentplanemeetsthewallopening\">S\u0131zd\u0131rmazl\u0131k d\u00fczleminin duvar a\u00e7\u0131kl\u0131\u011f\u0131yla birle\u015fti\u011fi yer<\/h2>\n<p>Yal\u0131t\u0131m d\u00fczlemi, biyog\u00fcvenlik bariyerinin bir odan\u0131n \u00e7evresinde kesintisiz olarak uzand\u0131\u011f\u0131 varsay\u0131msal y\u00fczeydir. Bir kablo veya kordon ge\u00e7i\u015finin bu d\u00fczlemi kesti\u011fi noktada, duvar a\u00e7\u0131kl\u0131\u011f\u0131, man\u015fon ve ge\u00e7i\u015f tertibat\u0131n\u0131n t\u00fcm\u00fc tek bir aray\u00fcze aittir; ancak bunlar genellikle, her biri sadece kendi k\u0131sm\u0131n\u0131 g\u00f6ren farkl\u0131 meslek gruplar\u0131 taraf\u0131ndan fiyatland\u0131r\u0131l\u0131r ve monte edilir. Genel m\u00fcteahhit, kesilmesi gereken bir delik g\u00f6r\u00fcr. Elektrik veya proses uzman\u0131 ise d\u00f6\u015fenmesi gereken bir kablo kanal\u0131 g\u00f6r\u00fcr. Muhafaza ekipman\u0131 tedarik\u00e7isi ise teslim etmesi gereken s\u0131zd\u0131rmaz bir ge\u00e7i\u015f sistemi g\u00f6r\u00fcr. Bu i\u015f b\u00f6l\u00fcm\u00fc ger\u00e7ekle\u015fmeden \u00f6nce muhafaza d\u00fczleminin kendisi duvar detay\u0131nda i\u015faretlenmemi\u015fse, her bir uzmanl\u0131k alan\u0131 aray\u00fcz\u00fc makul bir \u015fekilde farkl\u0131 \u015fekilde yorumlayabilir ve \u00e7izim koordinasyon sorunu, bunun yerine \u015fantiye koordinasyon sorununa d\u00f6n\u00fc\u015f\u00fcr.<\/p>\n<p>Bu \u00f6nemli bir husustur, \u00e7\u00fcnk\u00fc karar\u0131 y\u00f6nlendiren ama\u00e7 biyog\u00fcvenlik \u00f6nlemleridir; aseptik \u00fcr\u00fcn korumas\u0131 de\u011fildir. Mesele, ba\u011flant\u0131 noktas\u0131n\u0131n \u00fcr\u00fcn\u00fc steril tutup tutmad\u0131\u011f\u0131 de\u011fil; monte edilmi\u015f duvar, man\u015fon ve contan\u0131n, kapal\u0131 alan\u0131 d\u0131\u015f ortamdan ay\u0131ran bariyerin b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc koruyup korumad\u0131\u011f\u0131d\u0131r. Bu ayr\u0131m, aray\u00fczde \u201cdo\u011fru\u201d olan\u0131n neye benzedi\u011fini de\u011fi\u015ftirir. Aseptik bariyer aray\u00fcz\u00fc, \u00fcr\u00fcn\u00fcn maruz kalmas\u0131 \u00fczerindeki etkisine g\u00f6re de\u011ferlendirilir; muhafaza bariyer aray\u00fcz\u00fc ise odan\u0131n bir b\u00fct\u00fcn olarak s\u0131zd\u0131rmazl\u0131\u011f\u0131 \u00fczerindeki etkisine g\u00f6re de\u011ferlendirilir. <a href=\"https:\/\/www.efbs.admin.ch\/inhalte\/dokumentation\/empfehlungen\/Empfehlungen_aktuell\/Structural_and_Technical_Safety_Measures_BSL3_E.pdf\">\u0130svi\u00e7re Biyog\u00fcvenlik Uzman Komitesi\u2019nin BSL-3 yap\u0131sal ve teknik g\u00fcvenlik \u00f6nlemlerine ili\u015fkin tavsiyesi<\/a> kablo ve medya ge\u00e7i\u015flerini, s\u0131zd\u0131rmazl\u0131k s\u0131n\u0131r\u0131n\u0131n bir par\u00e7as\u0131 olarak ele al\u0131r; bunlar\u0131n say\u0131s\u0131, ayr\u0131lm\u0131\u015f a\u00e7\u0131kl\u0131klar, kullan\u0131lan s\u0131zd\u0131rmazl\u0131k malzemeleri ve tamamlanm\u0131\u015f odan\u0131n s\u0131zd\u0131rmazl\u0131\u011f\u0131 gibi unsurlar\u0131n t\u00fcm\u00fcn\u00fcn tasar\u0131m a\u015famas\u0131nda dikkate al\u0131nmas\u0131 gerekti\u011fini belirtir. Bu yakla\u015f\u0131m, d\u00fczlemin erken a\u015famada belirlenmesini destekler: Bir ge\u00e7i\u015f, i\u00e7inde bir ba\u011flant\u0131 par\u00e7as\u0131 bulunan bir delik olarak de\u011fil, s\u0131n\u0131r\u0131n bir par\u00e7as\u0131 olarak anla\u015f\u0131l\u0131rsa; a\u00e7\u0131kl\u0131k, man\u015fon ve s\u0131zd\u0131rmazl\u0131k eleman\u0131 art\u0131k ayr\u0131 i\u015f kapsamlar\u0131 olmaktan \u00e7\u0131kar ve bir b\u00fct\u00fcn olarak planlanmas\u0131 gereken tek bir aray\u00fcz haline gelir.<\/p>\n<p>Bir projede d\u00fczlem, a\u00e7\u0131k\u00e7a belirtilmi\u015f de\u011fil de z\u0131mni olarak ele al\u0131nd\u0131\u011f\u0131nda, pratikte ortaya \u00e7\u0131kan risk tek bir ar\u0131zal\u0131 bile\u015fenden ziyade, her biri teknik olarak savunulabilir bir aray\u00fcz par\u00e7as\u0131 olu\u015fturan ancak bir araya getirildi\u011finde kesintisiz bir s\u0131n\u0131r olu\u015fturmayan bir dizi i\u015f kolundan kaynaklan\u0131r. D\u00fczlemin a\u00e7\u0131k\u00e7a belirtildi\u011fi ve a\u00e7\u0131kl\u0131k, man\u015fon ve ge\u00e7i\u015f i\u015fleri i\u00e7in kapsam b\u00f6l\u00fcnmesinde referans olarak kullan\u0131ld\u0131\u011f\u0131 durumlarda, her i\u015f kolu ayn\u0131 referansa g\u00f6re fiyatland\u0131rma yapar ve montaj\u0131 ger\u00e7ekle\u015ftirir; b\u00f6ylece anla\u015fmazl\u0131klar duvarda ortaya \u00e7\u0131kmadan \u00f6nce ka\u011f\u0131t \u00fczerinde g\u00fcn y\u00fcz\u00fcne \u00e7\u0131kar.<\/p>\n\t\t<div data-elementor-type=\"widget\" data-elementor-id=\"6744\" class=\"elementor elementor-6744\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6744 elementor-align-right elementor-widget elementor-widget-button\" data-id=\"6744\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjI1MzMiLCJ0b2dnbGUiOmZhbHNlfQ%3D%3D\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u015eimdi Sorgula<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n<h2 id=\"sleeveandopeningdimensionseachtrademustconfirm\">Her bir ticaretin kol ve a\u00e7\u0131kl\u0131k boyutlar\u0131n\u0131 teyit etmesi gerekir<\/h2>\n<p>Belirli bir man\u015fon ve a\u00e7\u0131kl\u0131k geometrisine g\u00f6re bir Vacu-Pass konfig\u00fcrasyonu se\u00e7ilir ve bu geometri, sadece \u00e7izimdeki haliyle de\u011fil, fiilen in\u015fa edilenle de uyumlu olmal\u0131d\u0131r. Bu kontrol\u00fcn a\u011f\u0131rl\u0131\u011f\u0131n\u0131 iki boyut ta\u015f\u0131r: in\u015fa edildi\u011fi haliyle duvar a\u00e7\u0131kl\u0131\u011f\u0131 ve in\u015fa edildi\u011fi haliyle man\u015fon; her ikisi de sipari\u015f edilen konfig\u00fcrasyonla kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. Bu, iki ba\u011f\u0131ms\u0131z kontrolden ziyade birbiriyle ba\u011flant\u0131l\u0131 bir kontrold\u00fcr; \u00e7\u00fcnk\u00fc tek ba\u015f\u0131na do\u011fru olan ancak yanl\u0131\u015f boyutlu bir a\u00e7\u0131kl\u0131\u011fa monte edilmi\u015f bir man\u015fon ya da do\u011fru olan ancak yanl\u0131\u015f man\u015fonla donat\u0131lm\u0131\u015f bir a\u00e7\u0131kl\u0131k, pratikte ayn\u0131 sonucu do\u011furur \u2014 kablolar i\u00e7inden ge\u00e7irildikten sonra tasar\u0131mda \u00f6ng\u00f6r\u00fcld\u00fc\u011f\u00fc gibi s\u0131zd\u0131rmaz hale getirilemeyen bir ge\u00e7i\u015f.<\/p>\n<p>Bu yarg\u0131y\u0131 de\u011fi\u015ftiren ko\u015ful, zamanlamad\u0131r. Kablolar \u00e7ekilmeden \u00f6nce fiili boyutlar se\u00e7ilen konfig\u00fcrasyonla kar\u015f\u0131la\u015ft\u0131r\u0131larak do\u011frulan\u0131rsa, bir uyumsuzluk sadece evrak \u00fczerinde bir d\u00fczeltme gerektirir. Kablolar \u00e7ekildikten sonra fark edilirse, bunu d\u00fczeltmek, yeniden i\u015flenmesi gereken bir a\u00e7\u0131kl\u0131\u011fa veya man\u015fona ula\u015fmak i\u00e7in tamamlanm\u0131\u015f kablo d\u00f6\u015femelerini bozmak anlam\u0131na gelir. Genel in\u015faat s\u0131ras\u0131 \u2014 kaba a\u00e7\u0131kl\u0131k, man\u015fon montaj\u0131, kablo \u00e7ekme, s\u0131zd\u0131rmazl\u0131k \u2014 fiziksel i\u015fin do\u011fas\u0131 gere\u011fi b\u00f6yle bir zorunluluk olmamas\u0131na ra\u011fmen, pratikte bu s\u00fcreci tek y\u00f6nl\u00fc hale getirir. Boyutlar\u0131n erken a\u015famada teyit edilmesi, teknik bir karar oldu\u011fu kadar bir zamanlama karar\u0131d\u0131r da.<\/p>\n<p>Bu do\u011frulamay\u0131 kimin yapaca\u011f\u0131, varsay\u0131lan bir ayar de\u011fil, proje kapsam\u0131nda al\u0131nacak bir karard\u0131r. \u0130n\u015faat i\u015f\u00e7ileri mimari \u00e7izimlere g\u00f6re do\u011frulama yapar; kurulumunu yapan taraf ise <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/how-vacu-pass-cable-ports-work-installation-basics\/\">Vacu-Pass donan\u0131m\u0131<\/a> ekipman\u0131n kendi konfig\u00fcrasyon kayd\u0131yla kar\u015f\u0131la\u015ft\u0131rarak do\u011frular; ancak bu kontrollerden hi\u00e7biri tek ba\u015f\u0131na, in\u015fa edilen a\u00e7\u0131kl\u0131\u011f\u0131n se\u00e7ilen \u00fcr\u00fcnle uyumlu oldu\u011funu teyit etmez. Bir projede, in\u015fa sonras\u0131 durumu se\u00e7ilen Vacu-Pass konfig\u00fcrasyonuyla kar\u015f\u0131la\u015ft\u0131rmaktan sorumlu, ad\u0131 belirtilen bir taraf bulunmal\u0131d\u0131r; bu kar\u015f\u0131la\u015ft\u0131rma, man\u015fonun do\u011fru oldu\u011fu varsay\u0131m\u0131yla bir kablo \u00e7ekme s\u0131ras\u0131na ba\u015flanmadan \u00f6nce, d\u00fczeltmenin h\u00e2l\u00e2 kolay oldu\u011fu bir a\u015famada ger\u00e7ekle\u015ftirilmelidir.<\/p>\n<h2 id=\"conduitendsandcablepullaccessatthetransit\">Ge\u00e7i\u015f noktas\u0131nda boru u\u00e7lar\u0131 ve kablo \u00e7ekme giri\u015fi<\/h2>\n<table>\n<thead>\n<tr>\n<th>Aray\u00fcz<\/th>\n<th>Karar veya \u00e7\u00f6z\u00fcm i\u00e7in kontrol<\/th>\n<th>S\u0131n\u0131r\u0131n g\u00f6r\u00fcn\u00fcr kalmas\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Duvar y\u00fczeyinde yap\u0131lan servis<\/td>\n<td>Hizmet hatt\u0131n\u0131n duvar y\u00fczeyine nas\u0131l sabitlenece\u011fine karar verin.<\/td>\n<td>Bu, kablo kanal\u0131 ba\u011flant\u0131 noktalar\u0131ndan ve kablo kanal\u0131 i\u00e7indeki herhangi bir s\u0131zd\u0131rmazl\u0131k eleman\u0131ndan ayr\u0131 bir konudur.<\/td>\n<\/tr>\n<tr>\n<td>Kablo kanal\u0131 sonland\u0131rmas\u0131 ve i\u00e7 k\u0131sm\u0131<\/td>\n<td>Kanal\u0131n nerede sona erece\u011fine ve i\u00e7indeki bir s\u0131zd\u0131rmazl\u0131k eleman\u0131n\u0131n tasar\u0131m\u0131n bir par\u00e7as\u0131 olup olmad\u0131\u011f\u0131na karar verin.<\/td>\n<td>Duvar y\u00fczeyindeki hizmet m\u00fchr\u00fc, bu ayr\u0131 soruyu \u00e7\u00f6z\u00fcme kavu\u015fturmamaktad\u0131r.<\/td>\n<\/tr>\n<tr>\n<td>Aktarma noktas\u0131nda halatl\u0131 eri\u015fim<\/td>\n<td>Ge\u00e7i\u015f noktas\u0131nda eri\u015fim yetkisi verin; kablolar \u00e7ekilmeden \u00f6nce, mevcut a\u00e7\u0131kl\u0131k ve man\u015fon boyutlar\u0131n\u0131 se\u00e7ilen Vacu-Pass konfig\u00fcrasyonuyla kar\u015f\u0131la\u015ft\u0131rarak do\u011frulay\u0131n.<\/td>\n<td>Bir nakliye teklifi tek ba\u015f\u0131na, a\u00e7ma, man\u015fon veya boru ucu i\u015flerini kapsamaz.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Tek bir ge\u00e7i\u015f teklifi veya \u00e7izim notu, hizmet hatt\u0131n\u0131n duvar\u0131 ge\u00e7ti\u011fi noktadaki s\u0131zd\u0131rmazl\u0131k i\u015fleminin t\u00fcm ge\u00e7i\u015f sorununu \u00e7\u00f6zd\u00fc\u011f\u00fc izlenimini yaratabilir. Ancak durum b\u00f6yle de\u011fildir. Kablo veya kordonu duvardan ge\u00e7irmek i\u00e7in bir kablo kanal\u0131 kullan\u0131ld\u0131\u011f\u0131nda, ayn\u0131 fiziksel konumda en az \u00fc\u00e7 ayr\u0131 sorun ortaya \u00e7\u0131kar; ancak bunlar ayn\u0131 tasar\u0131m karar\u0131 kapsam\u0131nda de\u011fildir.<\/p>\n<p>Birincisi, hizmet hatt\u0131n\u0131n \u2014 kordon, kablo veya boru kanal\u0131 \u2014 duvar y\u00fczeyinde nas\u0131l s\u0131zd\u0131rmaz hale getirildi\u011fidir; bu i\u015flevi yerine getirmek \u00fczere Vacu-Pass ba\u011flant\u0131 noktas\u0131 se\u00e7ilmi\u015ftir. \u0130kincisi, boru kanal\u0131n\u0131n nerede sona erdi\u011fi ve duvar y\u00fczeyi s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131n yukar\u0131s\u0131nda veya a\u015fa\u011f\u0131s\u0131nda, boru kanal\u0131n\u0131n i\u00e7 k\u0131sm\u0131nda herhangi bir s\u0131zd\u0131rmazl\u0131k gerekip gerekmedi\u011fidir. \u00dc\u00e7\u00fcnc\u00fcs\u00fc ise, kablonun i\u00e7inden ge\u00e7irilmesi i\u00e7in ge\u00e7i\u015f noktas\u0131nda ne kadar eri\u015fim alan\u0131 kald\u0131\u011f\u0131 ve duvar y\u00fczeyi s\u0131zd\u0131rmazl\u0131\u011f\u0131 sa\u011fland\u0131ktan sonra bu eri\u015fim alan\u0131n\u0131n korunup korunmayaca\u011f\u0131 ya da kapat\u0131l\u0131p kapat\u0131lmayaca\u011f\u0131d\u0131r. Bunlar, duvar\u0131n ayn\u0131 birka\u00e7 santimetrelik b\u00f6l\u00fcm\u00fcn\u00fc i\u015fgal ettikleri i\u00e7in tek bir soru olarak ele al\u0131nd\u0131\u011f\u0131nda, boru kanal\u0131 d\u00f6\u015feyen meslek grubu, kablo \u00e7eken meslek grubu ve s\u0131zd\u0131rmazl\u0131k s\u0131zd\u0131rmazl\u0131\u011f\u0131ndan sorumlu taraf aras\u0131nda kapsam farkl\u0131l\u0131klar\u0131 ortaya \u00e7\u0131kmaktad\u0131r.<\/p>\n<p>Bu sorular\u0131 net bir \u015fekilde ay\u0131ran ko\u015ful, duvar\u0131n \u00f6tesine uzanan bir kablo kanal\u0131 olup olmad\u0131\u011f\u0131d\u0131r. Kablo veya kordonun kablo kanal\u0131 olmadan do\u011frudan ba\u011flant\u0131 noktas\u0131ndan ge\u00e7ti\u011fi durumlarda, duvar y\u00fczeyi s\u0131zd\u0131rmazl\u0131\u011f\u0131 aray\u00fcz\u00fcn tamam\u0131na yak\u0131nd\u0131r ve ge\u00e7i\u015f \u015fartnamesi sonucu b\u00fcy\u00fck \u00f6l\u00e7\u00fcde belirler. Kanal\u0131n bir veya her iki tarafta kullan\u0131ld\u0131\u011f\u0131 durumlarda, duvar y\u00fczeyi s\u0131zd\u0131rmazl\u0131\u011f\u0131 yaln\u0131zca s\u0131n\u0131r ge\u00e7i\u015fini belirler; kanal\u0131n kendisi, kendi \u015fartlar\u0131 kapsam\u0131nda ele al\u0131nmad\u0131\u011f\u0131 takdirde ayr\u0131 bir s\u0131z\u0131nt\u0131 yoludur, \u00e7\u00fcnk\u00fc kanal, etraf\u0131ndaki duvar y\u00fczeyi s\u0131zd\u0131rmazl\u0131\u011f\u0131 sa\u011flam olsa bile i\u00e7inden hava veya buhar ge\u00e7irebilir. Kanal sonland\u0131rmas\u0131n\u0131 ve kanal i\u00e7i s\u0131zd\u0131rmazl\u0131\u011f\u0131 ayr\u0131 olarak belirtmeden sadece \u201cba\u011flant\u0131 noktas\u0131n\u0131 s\u0131zd\u0131rmaz hale getirin\u201d ifadesini i\u00e7eren bir proje kapsam\u0131, asl\u0131nda bu ikinci g\u00f6revi kimseye atamam\u0131\u015f demektir.<\/p>\n<p>Kablo \u00e7ekme i\u00e7in eri\u015fim, konuyla ilgili ancak ayr\u0131 bir karard\u0131r. S\u0131zd\u0131rmazl\u0131k bile\u015fenlerinin \u00e7ok erken kapat\u0131lmas\u0131, bitmi\u015f s\u0131zd\u0131rmazl\u0131\u011f\u0131 bozmadan daha sonra kablo ekleme veya de\u011fi\u015ftirme imk\u00e2n\u0131n\u0131 ortadan kald\u0131r\u0131r; eri\u015fimin gere\u011finden fazla a\u00e7\u0131k b\u0131rak\u0131lmas\u0131 ise o konumdaki s\u0131zd\u0131rmazl\u0131k s\u0131n\u0131r\u0131n\u0131n eksik kald\u0131\u011f\u0131 s\u00fcreyi uzat\u0131r. Kablo \u00e7ekme eri\u015fiminin ne kadar s\u00fcreyle a\u00e7\u0131k kalaca\u011f\u0131na ve bunu kapatmaktan kimin sorumlu olaca\u011f\u0131na ili\u015fkin karar, yaln\u0131zca ekipman spesifikasyonuna de\u011fil, kurulum s\u0131ras\u0131n\u0131 y\u00f6neten tarafa aittir.<\/p>\n<h2 id=\"sealassemblyandinspectionbeforetheinterfaceisconcealed\">Aray\u00fcz gizlenmeden \u00f6nce conta montaj\u0131 ve kontrol\u00fc<\/h2>\n<table>\n<thead>\n<tr>\n<th>Kontrol et<\/th>\n<th>Proje eylemi<\/th>\n<th>Kan\u0131t s\u0131n\u0131r\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>G\u00f6rsel inceleme<\/td>\n<td>Gizleme i\u015fleminden \u00f6nce, kablo kanallar\u0131 ve kablolama ba\u011flant\u0131 noktalar\u0131 da dahil olmak \u00fczere, tamamlanm\u0131\u015f bariyer ge\u00e7i\u015finin denetimini sa\u011flay\u0131n.<\/td>\n<td>Kanada Biyog\u00fcvenlik Standard\u0131, izolasyon b\u00f6lgelerine uygulanabilirlik ve istisnalar i\u00e7ermektedir; ancak bir kurulumcu atamamaktad\u0131r.<\/td>\n<\/tr>\n<tr>\n<td>Uygun oldu\u011fu durumlarda m\u00fch\u00fcr do\u011frulamas\u0131<\/td>\n<td>Duvara monte edilmi\u015f s\u0131zd\u0131rmazl\u0131k kontrol\u00fcn\u00fc, fiili montaj durumuyla kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/td>\n<td>Do\u011frulama \u015fartl\u0131d\u0131r; burada evrensel bir kabul de\u011feri belirtilmemi\u015ftir.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Man\u015fon yerle\u015ftirildikten, kablo kanal\u0131 sonland\u0131r\u0131ld\u0131ktan ve kablo \u00e7ekildikten sonra, ba\u011flant\u0131 noktas\u0131 genellikle gizlenece\u011fi bir noktaya ula\u015f\u0131r \u2014 bitmi\u015f duvar y\u00fczeyinin arkas\u0131nda, yal\u0131t\u0131m\u0131n arkas\u0131nda ya da basit\u00e7e in\u015faat\u0131n bir sonraki a\u015famas\u0131n\u0131n arkas\u0131nda. Bu gizleme i\u015flemi ger\u00e7ekle\u015fmeden \u00f6nce, iki farkl\u0131 kontrol yap\u0131labilir ve bunlar farkl\u0131 sorulara yan\u0131t verir.<\/p>\n<p>G\u00f6zle yap\u0131lan inceleme, montaj\u0131n belirtildi\u011fi gibi oldu\u011funu do\u011frulamaktad\u0131r: man\u015fon do\u011fru \u015fekilde yerle\u015ftirilmi\u015ftir, s\u0131zd\u0131rmazl\u0131k malzemesi olmas\u0131 gereken yere konulmu\u015ftur, kablo kanal\u0131 u\u00e7lar\u0131 g\u00f6r\u00fcn\u00fcr ve eri\u015filebilir durumdad\u0131r ve fiziksel montaj\u0131n hi\u00e7bir y\u00f6n\u00fc tasar\u0131mdan sapma g\u00f6stermemektedir. Bu <a href=\"https:\/\/www.canada.ca\/en\/public-health\/services\/canadian-biosafety-standards-guidelines\/third-edition.html\">Kanada Biyog\u00fcvenlik Standard\u0131, \u00dc\u00e7\u00fcnc\u00fc Bask\u0131<\/a>, bariyer ge\u00e7i\u015flerini g\u00f6rsel incelemeye tabi tutar ve uygun oldu\u011fu durumlarda, \u00f6zellikle kablo kanallar\u0131 ve kablolama ba\u011flant\u0131 noktalar\u0131 dahil olmak \u00fczere, \u015fartl\u0131 s\u0131zd\u0131rmazl\u0131k do\u011frulamas\u0131na tabi k\u0131lar. Bu inceleme kapsam\u0131, standard\u0131n kendi uygulanabilirlik ve istisnalar b\u00f6l\u00fcm\u00fc kapsam\u0131nda muhafaza b\u00f6lgeleri i\u00e7in belirtilmi\u015ftir; bu h\u00fck\u00fcm tek ba\u015f\u0131na incelemeyi hangi proje taraf\u0131n\u0131n ger\u00e7ekle\u015ftirece\u011fini belirlemez veya belirtilen kapsam\u0131n d\u0131\u015f\u0131nda evrensel bir kabul de\u011feri ta\u015f\u0131maz.<\/p>\n<p>Conta do\u011frulamas\u0131, montaj\u0131n incelenmesinden ayr\u0131 ve ko\u015fullu bir kontrold\u00fcr. Bir projede monte edilmi\u015f contan\u0131n performans\u0131n\u0131n do\u011frulanmas\u0131 gerekti\u011finde, bu kontrol, Vacu-Pass ba\u011flant\u0131 noktas\u0131n\u0131n tek ba\u015f\u0131na neler yapabilece\u011fine dair genel bir beklentiye de\u011fil, fiili montaj durumuna \u2014 yani in\u015fa edildi\u011fi \u015fekliyle spesifik man\u015fon, conta malzemesi ve kablo kanal\u0131 konfig\u00fcrasyonuna \u2014 dayand\u0131r\u0131lmal\u0131d\u0131r. Kendi yeterlilik testinde ama\u00e7land\u0131\u011f\u0131 gibi performans g\u00f6steren bir ba\u011flant\u0131 noktas\u0131, tek ba\u015f\u0131na, man\u015fon, duvar malzemesi ve contadan olu\u015fan belirli bir saha montaj\u0131n\u0131n ayn\u0131 ko\u015fulu kar\u015f\u0131lad\u0131\u011f\u0131n\u0131 kan\u0131tlamaz; kontrol edilen, bile\u015fenin nominal kapasitesi de\u011fil, monte edilmi\u015f durumdur.<\/p>\n<p>Bunun planlama \u00fczerindeki sonucu a\u00e7\u0131kt\u0131r: Hem denetim hem de m\u00fch\u00fcr do\u011frulamas\u0131, montaj h\u00e2l\u00e2 g\u00f6r\u00fcn\u00fcr ve eri\u015filebilir durumdayken ger\u00e7ekle\u015ftirilmelidir. Herhangi bir kontrol \u00f6ncesinde \u00f6rtme i\u015flemi ger\u00e7ekle\u015firse, proje, as-built durumunu do\u011frudan teyit etme imk\u00e2n\u0131n\u0131 yitirir ve g\u00f6zlem yerine belgelere dayanarak bu durumu \u00e7\u0131karsamak zorunda kal\u0131r. Bu denetim aral\u0131\u011f\u0131n\u0131 kimin ayarlayaca\u011f\u0131 ve \u015fartl\u0131 m\u00fch\u00fcr do\u011frulamas\u0131n\u0131 kimin ger\u00e7ekle\u015ftirece\u011finin belirlenmesi, in\u015faat program\u0131 \u00f6rtme a\u015famas\u0131na ula\u015fmadan \u00f6nce al\u0131nmas\u0131 gereken bir proje karar\u0131d\u0131r; bu karar, \u00f6rtme a\u015famas\u0131ndan sonra al\u0131nmamal\u0131d\u0131r.<\/p>\n<h2 id=\"responsibilitymatrixforinstalledwallverificationandhandoff\">Duvara monte edilmi\u015f sistemlerin do\u011frulanmas\u0131 ve devri i\u00e7in sorumluluk matrisi<\/h2>\n<table>\n<thead>\n<tr>\n<th>Duvar aray\u00fcz \u00f6\u011fesi<\/th>\n<th>Proje partisi veya ticari etkinlik ad\u0131<\/th>\n<th>Atamak i\u00e7in kontrol edin veya devredin<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Muhafaza d\u00fczlemi ve a\u00e7\u0131kl\u0131k<\/td>\n<td>Duvar detay\u0131nda s\u0131n\u0131r d\u00fczlemini i\u015faretleyen ve a\u00e7ma i\u015flerini y\u00fcr\u00fcten ki\u015fiyi belirtin.<\/td>\n<td>A\u00e7\u0131kl\u0131k, man\u015fon ve ge\u00e7i\u015f kapsam\u0131n\u0131 ay\u0131rmadan \u00f6nce s\u0131n\u0131r\u0131 belirleyin.<\/td>\n<\/tr>\n<tr>\n<td>Man\u015fon ve as-built boyutlar\u0131<\/td>\n<td>Man\u015fonu kimin haz\u0131rlayaca\u011f\u0131n\u0131 ve as-built a\u00e7\u0131kl\u0131k ile man\u015fon boyutlar\u0131n\u0131 kimin do\u011frulayaca\u011f\u0131n\u0131 belirtin.<\/td>\n<td>Kablolar \u00e7ekilmeden \u00f6nce, se\u00e7ilen Vacu-Pass yap\u0131land\u0131rmas\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/td>\n<\/tr>\n<tr>\n<td>Duvar y\u00fczeyindeki ge\u00e7i\u015f contas\u0131<\/td>\n<td>Duvar y\u00fczeyindeki ba\u011flant\u0131 noktas\u0131 \u00e7evresindeki contay\u0131 monte eden ki\u015finin ad\u0131n\u0131 belirtin.<\/td>\n<td>Gizlemeden \u00f6nce inceleme amac\u0131yla eri\u015fimi koruyun.<\/td>\n<\/tr>\n<tr>\n<td>Kablo kanal\u0131 u\u00e7 ba\u011flant\u0131s\u0131 ve kanal i\u00e7i s\u0131zd\u0131rmazl\u0131k<\/td>\n<td>Kablo kanal\u0131 sonland\u0131rma sorununu ve kablo kanal\u0131 i\u00e7i s\u0131zd\u0131rmazl\u0131k sorununu kimin \u00e7\u00f6zece\u011fini belirtin.<\/td>\n<td>Duvar y\u00fczeyi contas\u0131n\u0131 bu sorunun \u00e7\u00f6z\u00fcm\u00fc olarak kabul etmeyin.<\/td>\n<\/tr>\n<tr>\n<td>Penetrasyon tamamland\u0131<\/td>\n<td>Monte edilmi\u015f duvar kontrol\u00fcn\u00fc kimin yapt\u0131\u011f\u0131n\u0131, denetim eri\u015fimini kimin sa\u011flad\u0131\u011f\u0131n\u0131, denetimi kimin ger\u00e7ekle\u015ftirdi\u011fini ve bu kontrol\u00fcn sorumlulu\u011funun kime ait oldu\u011funu belirtin.<\/td>\n<td>Teslimattan \u00f6nce kontrol\u00fc, \u00fcr\u00fcn\u00fcn fiilen monte edilmi\u015f durumuyla kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A\u00e7\u0131l\u0131\u015f, man\u015fon, s\u0131zd\u0131rmazl\u0131k, boru kanal\u0131 ve denetim konular\u0131n\u0131 bir araya getirdi\u011fimizde ortaya \u00e7\u0131kan temel \u00f6r\u00fcnt\u00fc \u015fudur: Hi\u00e7bir tek bir i\u015f kolu veya tedarik\u00e7i kapsam\u0131 do\u011fal olarak bunlar\u0131n hepsini kapsamaz ve at\u0131fta bulunulan hi\u00e7bir standart da bunlar\u0131 bir i\u015f koluna atamaz. \u0130svi\u00e7re tavsiyesi ve Kanada Biyog\u00fcvenlik Standard\u0131, her ikisi de muhafaza s\u0131n\u0131r\u0131n\u0131n neye ihtiya\u00e7 duydu\u011funu a\u00e7\u0131klamaktad\u0131r \u2014 birinde penetrasyon say\u0131s\u0131na ve s\u0131zd\u0131rmazl\u0131k malzemelerine dikkat edilmesi, di\u011ferinde ise denetim ve ko\u015fullu s\u0131zd\u0131rmazl\u0131k do\u011frulamas\u0131 \u2014 ancak bu i\u015fi hangi proje taraf\u0131n\u0131n ger\u00e7ekle\u015ftirece\u011fini belirtmemektedir. Bu g\u00f6revlendirme, i\u015fler farkl\u0131 meslek gruplar\u0131 aras\u0131nda payla\u015ft\u0131r\u0131lmadan \u00f6nce, bir kez yaz\u0131l\u0131 olarak al\u0131nan bir proje y\u00f6netimi karar\u0131d\u0131r.<\/p>\n<p>Pratik da\u011f\u0131l\u0131m, halihaz\u0131rda belirlenmi\u015f olan ayn\u0131 b\u00f6l\u00fcmlere g\u00f6re yap\u0131l\u0131r: Ad\u0131 belirtilen bir taraf, muhafaza d\u00fczlemini i\u015faretler ve a\u00e7\u0131kl\u0131\u011f\u0131n sorumlulu\u011funu \u00fcstlenir; ad\u0131 belirtilen bir taraf, man\u015fonu y\u00f6netir ve se\u00e7ilen konfig\u00fcrasyona g\u00f6re man\u015fonun as-built boyutlar\u0131n\u0131 do\u011frular; ad\u0131 belirtilen bir taraf, duvar y\u00fczeyinde contay\u0131 monte eder; ad\u0131 belirtilen bir taraf, duvar y\u00fczeyi contas\u0131ndan ayr\u0131 tutulacak \u015fekilde kablo kanal\u0131 sonland\u0131rmas\u0131n\u0131 ve kanal i\u00e7i contalar\u0131n\u0131 halleder; ve ad\u0131 belirtilen bir taraf, tamamlanm\u0131\u015f montaj\u0131 korur, denetim eri\u015fimi sa\u011flar ve kapama i\u015fleminden \u00f6nce denetimi ger\u00e7ekle\u015ftirir. Bir projenin Vacu-Pass konfig\u00fcrasyonu ve kablo veya kordon gereksinimleri erken a\u015famada tan\u0131mland\u0131\u011f\u0131nda, bu proje bilgileri ba\u011flant\u0131 noktas\u0131 i\u00e7in yap\u0131lan konfig\u00fcrasyon ve teklif incelemesine dahil edilir; bu sayede tedarik\u00e7inin incelemesi, saha do\u011frulamas\u0131n\u0131n dayand\u0131\u011f\u0131 ayn\u0131 \u201cas-built\u201d ba\u011flam\u0131na sahip olur.<\/p>\n<p>Bir projede tek bir i\u015f kolunun tek bir s\u00f6zle\u015fme kapsam\u0131nda t\u00fcm duvar paketini y\u00f6netmesi durumunda, bunun pratikteki sonucu, bu devir teslim i\u015flemlerinin s\u00f6z konusu i\u015f kolunun kendi b\u00fcnyesinde kalmas\u0131d\u0131r; bu durumda gerekli olan temel husus, ayr\u0131 taraflar aras\u0131ndaki s\u0131n\u0131rlar\u0131 m\u00fczakere etmekten ziyade her bir kontrol\u00fcn belgelenmesidir. Bir projede in\u015faat, elektrik veya proses i\u015f kollar\u0131 ile muhafaza ekipman\u0131 tedarik\u00e7isi ayr\u0131 s\u00f6zle\u015fmelere b\u00f6l\u00fcnd\u00fc\u011f\u00fcnde, ayn\u0131 be\u015f unsur \u2014 d\u00fczlem ve a\u00e7\u0131kl\u0131k, man\u015fon boyutlar\u0131, duvar y\u00fczeyi s\u0131zd\u0131rmazl\u0131\u011f\u0131, kablo kanal\u0131 ve kanal i\u00e7i s\u0131zd\u0131rmazl\u0131\u011f\u0131, ve <a href=\"https:\/\/qualia-bio.com\/tr\/blog\/site-acceptance-testing-for-bsl-3-4-equipment-packages-utilities-interlocks-alarms-and-installation-checks\/\">montaj sonras\u0131 kontrol<\/a> \u2014 her birinin yine de belirli bir sorumlusu olmas\u0131 gerekir ve koordinasyon y\u00fck\u00fc, kaplama i\u015fleminden \u00f6nce s\u00f6zle\u015fmeler aras\u0131ndaki i\u015f kapsamlar\u0131n\u0131 uyumlu hale getirmekle y\u00fck\u00fcml\u00fc olan proje veya in\u015faat y\u00f6neticisine kayar. Her iki yap\u0131da da, kesinlikle atama yap\u0131lmadan b\u0131rak\u0131lmamas\u0131 gereken husus, fiili montaj durumuna ba\u011fl\u0131 olan \u201cmonte edilmi\u015f duvar\u201d kontrol\u00fcd\u00fcr; zira bu kontrol, aray\u00fcz\u00fcn \u00e7izimdeki haliyle de\u011fil, in\u015fa edildi\u011fi haliyle do\u011frulanmas\u0131n\u0131 sa\u011flar.<\/p>\n<h2 id=\"frequentlyaskedquestions\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<p><strong>Q:<\/strong> Vacu-Pass\u2019\u0131n ula\u015f\u0131m teklifi, duvar a\u00e7\u0131kl\u0131\u011f\u0131, man\u015fon ve kablo kanal\u0131 ucu i\u015flerini de kaps\u0131yor mu?<br \/>\n<strong>A:<\/strong> Hay\u0131r. Bir nakliye teklifi tek ba\u015f\u0131na bu g\u00f6revleri tahsis etmez. Duvar detay\u0131nda s\u0131n\u0131r d\u00fczlemini i\u015faretleyin, ard\u0131ndan kapsam\u0131n fiyatland\u0131r\u0131lmas\u0131 ve devredilmesinden \u00f6nce her bir aray\u00fczden sorumlu proje taraf\u0131n\u0131 veya i\u015f kolunu belirtin.<\/p>\n<p><strong>Q:<\/strong> Kablolar duvar ge\u00e7idinden ge\u00e7irmeden \u00f6nce nelerin kontrol edilmesi gerekir?<br \/>\n<strong>A:<\/strong> As-built a\u00e7\u0131kl\u0131k ve man\u015fon boyutlar\u0131n\u0131, se\u00e7ilen Vacu-Pass konfig\u00fcrasyonuyla kar\u015f\u0131la\u015ft\u0131rarak do\u011frulay\u0131n. Kablo \u00e7ekme i\u015flemi ba\u015flamadan \u00f6nce bu kontrol g\u00f6revini, ad\u0131 belirtilen bir proje taraf\u0131na atay\u0131n.<\/p>\n<p><strong>Q:<\/strong> Duvar y\u00fczeyindeki ba\u011flant\u0131 noktas\u0131n\u0131n \u00e7evresini s\u0131zd\u0131rmaz hale getirmek, kablo kanal\u0131 s\u0131zd\u0131rmazl\u0131\u011f\u0131 sorununu \u00e7\u00f6zer mi?<br \/>\n<strong>A:<\/strong> Hay\u0131r. Kabloluk u\u00e7land\u0131rmas\u0131 ve kabloluk i\u00e7indeki her t\u00fcrl\u00fc s\u0131zd\u0131rmazl\u0131k, birbirinden ayr\u0131 tasar\u0131m kararlar\u0131d\u0131r. Duvar y\u00fczeyi hizmet s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 her iki aray\u00fcz\u00fc de kaps\u0131yormu\u015f gibi de\u011ferlendirmek yerine, bunlar\u0131 a\u00e7\u0131k\u00e7a ele al\u0131n.<\/p>\n<p><strong>Q:<\/strong> Tamamlanan s\u0131zma gizlenmeden \u00f6nce ekip ne gibi \u00f6nlemler almal\u0131d\u0131r?<br \/>\n<strong>A:<\/strong> Kablo kanallar\u0131 ve kablolama ba\u011flant\u0131 noktalar\u0131 da dahil olmak \u00fczere, tamamlanm\u0131\u015f bariyer ge\u00e7i\u015finin g\u00f6zle muayenesine ili\u015fkin eri\u015fim ve sorumluluklar\u0131 belirleyin. Duvara monte edilmi\u015f s\u0131zd\u0131rmazl\u0131k kontrol\u00fcn\u00fcn ge\u00e7erli oldu\u011fu durumlarda, bunu fiili montaj durumuna g\u00f6re de\u011ferlendirin; sa\u011flanan referanslar evrensel bir kabul de\u011feri sunmamaktad\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>Bir transit teklifinde duvar a\u00e7\u0131kl\u0131\u011f\u0131, man\u015fon veya kablo kanal\u0131 ucu i\u015fleri yer almaz. Duvar kapat\u0131lmadan \u00f6nce, her bir i\u015f kolu i\u00e7in bir aray\u00fcz ve denetim devri belirleyin.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"n8n_meta_description":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-7774","post","type-post","status-publish","format-standard","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/comments?post=7774"}],"version-history":[{"count":1,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7774\/revisions"}],"predecessor-version":[{"id":7775,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/posts\/7774\/revisions\/7775"}],"wp:attachment":[{"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/media?parent=7774"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/categories?post=7774"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualia-bio.com\/tr\/wp-json\/wp\/v2\/tags?post=7774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}